![A.O. Smith 120 through 250 Series Installation, User And Service Manual Download Page 26](http://html.mh-extra.com/html/a-o-smith/120-through-250-series/120-through-250-series_installation-user-and-service-manual_447391026.webp)
24
Instruction
m
anu
al
BFC
3.4.3
Gas data
II
2H3P
description
Unit
BFC 28
BFC 30
BFC 50
BFC 60
BFC 80
BFC 100
BFC 120
Gas category 2H: G20 - 20 mbar
Diameter of the venturi restrictor
mm
-
-
-
-
8,60
8,60
8,60
Nominal load (
gross
)
k
W
3
2,2
3
3,3
5
2,2
6
3,3
8
6,6
1
05,5
1
28,8
Nominal output
kW
31,0
32,7
50,3
60,4
84,2
100,7
121,8
Supply pressure
mbar
20
20
20
20
20
20
20
CO
2
(full load)
Vol%
9,0 + 1,0
9,0 + 1,0
9,0 + 1,0
9,0 + 1,0
8,9 + 1,0
8,9 + 1,0
8,9 + 1,0
Gas consumption*
m
3
/h
3,1
3,2
5,0
6,0
8,3
10,1
12,3
Gas category 3P: G31 - 37 / 50 mbar
Diameter of the venturi restrictor
mm
6,00
6,00
6,00
6,00
6,60
6,60
6,60
Nominal load (
gross
)
k
W
3
1,5
3
2,6
5
1,1
6
2,0
8
4,8
1
03,3
1
26,1
Nominal output
kW
31,0
32,7
50,3
60,4
84,2
100,7
121,8
Supply pressure
mbar
37 / 50
37 / 50
37 / 50
37 / 50
37 / 50
37 / 50
37 / 50
Gas control valve pressure
mbar
12,0 + 2,0
12,0 + 2,0
12,0 + 2,0
12,0 + 2,0
-
-
-
CO
2
(full load)
Vol%
10,0 + 1,0
10,0 + 1,0
10,0 + 1,0
10,0 + 1,0
9,6 + 1,0
9,6 + 1,0
9,6 + 1,0
Gas consumption*
kh/h
2,3
2,3
3,7
4,4
6,1
7,4
9,0
(*) Based on 1013.25 mbar and 15°C.
Summary of Contents for 120 through 250 Series
Page 4: ...E2 ...
Page 6: ...4 Instruction manual BFC gis ...
Page 10: ...Contents 8 Instruction manual BFC ...
Page 31: ...Instruction manual BFC 29 is Installation types IMD 0789 R0 C43 C13 C53 B23 C33 ...
Page 48: ...Conversion to a different gas category 46 Instruction manual BFC 4 is ...
Page 58: ...Status of the water heater 56 Instruction manual BFC 8 gis ...
Page 62: ...Shutting down 60 Instruction manual BFC 10 gis ...
Page 74: ...Service program 72 Instruction manual BFC 12 is ...
Page 88: ...Service interval 86 Instruction manual BFC 14 is ...
Page 97: ...Instruction manual BFC 95 is ...
Page 102: ...Instruction manual BFC 100 ...