background image

12

WebGUI Control

System Settings Tab

This tab provides access to control a number of system 

configuration  controls  including  displaying  the  unit’s  serial 

number, modifying the web access privileges, changing the 

IP  configuration,  performing  a  factory  reset,  rebooting  the 

system, and updating the firmware.

1. Serial Number:

 Displays the unit’s serial number.

2. Web User Setting:

 This section provides a way to change 

the password for the Administrator account. Click on 

“Save”

 

to confirm and activate any changes made to these settings.

NOTE:

 The default password is 

“admin”.

3. Network:

 The IP Address, Netmask and Gateway can be 

set manually, or DHCP can be enabled for automatic IP Configuration if your local network supports it. Click on 

“Save”

 to confirm and 

activate any changes made to these settings.

Note:

 If the IP address is changed then the IP address required for WebGUI and Telnet access will also change accordingly.

4. System:

•  Reboot: 

Click this button to reboot the unit.

•  Factory Default:

 Click this button to reset the unit to the factory default settings.

5. Firmware Upgrade:

 To update the unit’s firmware, click the 

“Choose File”

 button to open the file selection window and then select 

the firmware update file (*.bin format) located on your local PC. After selecting the file, click the

 “Upgrade”

 button to begin the firmware 

update process. Once the process completes the unit will automatically reboot.

A

  

NEU

VIDEO

Summary of Contents for ANI-H-KIT

Page 1: ...ANI H KIT ANI H R4K HDMI over HDBaseT Receiver w IR RS 232 PoH PSE LAN Receiver ANI HV WP4K 4K UHD HDMI VGA over HDBaseT w Signal Event Automation 1 Gang Wallplate Switcher INSTRUCTION MANUAL A NeuVid...

Page 2: ...on 12 This unit should be installed in a cool dry place away from sources of excessive heat vibration dust moisture and cold Do not use the unit near stoves heat registers radiators or other heat prod...

Page 3: ...smitter PD may be powered locally or via 48V PoH from a compatible HDBaseT Receiver PSE which allows for greater flexibility in installations The unit can be controlled via the front panel button with...

Page 4: ...C Power Adaptor Power Cord Users Guide APPLICATIONS Household entertainment sharing and control Lecture halls auditoriums and classroom Houses of worship Conference rooms and boardrooms Hotel event sp...

Page 5: ...signal event automation via RS 232 or CEC w compatible Receiver USB port supports firmware update and powering of 5V 500mA devices Front panel LEDs indicate HDCP mode input source and power Controlla...

Page 6: ...d Resolutions 480i 60Hz 4K 60Hz 4 2 0 8 bit VGA 60Hz WUXGA 60Hz RB HDMI Cable Length 10M 1080p 60Hz 12 bit 5M 4K 60Hz 4 4 4 8 bit CAT5e 6 Cable Length 100M 1080p 60Hz 12 bit 70M 4K 60Hz 4 2 0 8 bit IR...

Page 7: ...t input Green indicates Follow Display mode orange indicates Follow Source mode off indicates HDCP is disabled SRC LED This LED indicates which source is currently selected Green indicates the HDMI in...

Page 8: ...other properly y DC 48V Plug the 48V DC power adapter into this port and connect it to an AC wall outlet for power u IR1 BLASTER Connect to the supplied IR Blaster cable for IR signal transmission Pla...

Page 9: ...ssignment Pin Assignment 1 NC 1 NC 2 Tx 2 Rx 3 Rx 3 Tx 4 NC 4 NC 5 GND 5 GND 6 NC 6 NC 7 NC 7 NC 8 NC 8 NC 9 NC 9 NC Baud Rate 115200bps Data Bit 8 bits Parity None Flow Control None Stop Bit 1 NOTE R...

Page 10: ...CP server To switch to DHCP mode please select DHCP from the IP mode drop down then click Save followed by Reboot WebGUI Hotkey Once you are satisfied with the network settings you may use them to con...

Page 11: ...e to confirm and activate any changes Auto Mode Enable or disable the auto input switching mode Audio Route Control the audio used when the HDMI input is active Selecting Bypass will use the HDMI sign...

Page 12: ...Available CEC commands are Power Off Turn off the connected HDMI display device Power On Turn on the connected HDMI display device Active Source Force the connected HDMI display device to switch to t...

Page 13: ...nected PC 3 EDID Mode This dropdown controls how EDIDs are assigned to the unit s Inputs All Selecting this will allow the assignment of a single EDID to all Inputs simultaneously Appoint Selecting th...

Page 14: ...Gateway can be set manually or DHCP can be enabled for automatic IP Configuration if your local network supports it Click on Save to confirm and activate any changes made to these settings Note If th...

Page 15: ...es and Searching for required files When complete the Telnet client should be installed in Windows In Mac OS X Click Go Applications Utilities Terminal Once in the Command Line Interface CLI type teln...

Page 16: ...SET NETMASK N1 Set the netmask address N1 X X X X X 0 255 GET NETMASK Show the current netmask SET GATEWAY N1 Set the gateway address N1 X X X X X 0 255 GET GATEWAY Show the current gateway SET IN N1...

Page 17: ...vailable values for N1 ON All mode OFF Appoint mode GET ALL IN EDID MODE Show the current state of the EDID assignment mode SET ALL IN EDID N1 Set the EDID to use when set to All mode Available values...

Page 18: ...olor bar SET FREERUN A TYPE Show the current freerun display color GET FREERUN LIST List all available freerun colors GET AUTOMATION EVENT LIST List all Automation Event types SET AUTOMATION EVENT N1...

Page 19: ...characters GET AUTOMATION EVENT N1 UART COMMAND Show the RS 232 command string to be sent when the specified Automation Event is activated Available values for N1 1 Power on 2 Out A source active 3 Ou...

Page 20: ...3 Out A source lost 1 CEC power off 2 CEC power on 3 CEC active source GET AUTOMATION EVENT N1 CEC COMMAND Set the RS 232 operation mode of the unit Available values for N1 1 Console Commands 2 Contro...

Page 21: ...19 w allplate CONNECTION DIAGRAM Connection Diagram A NEUVIDEO...

Page 22: ...20 receiver CONNECTION DIAGRAM Connection Diagram A NEUVIDEO...

Page 23: ...366x768 60 60 RB P P P 1440x900 60 60 RB P P P 1600x1200 60 P P P 1680x1050 60 60 RB P P P 1920x1200 60 RB P P P SUPPORTED TV RESOLUTION HZ HDMI INPUT VGA INPUT HDBASET OUTPUT 720 480p 60 P P P 720 57...

Page 24: ...100M 230 ft 70M CAT7 328 ft 100M 328 ft 100M Full HD Video 1080p Up to 1080p 60Hz 12 bit color Data rates lower than 5 3Gbps or below 225MHz TMDS clock Ultra HD Video 4K 4K 24 25 30Hz 4K 50 60Hz YUV...

Page 25: ...60 P P 1080i 50 60 P P 1080p 50 60 P P 1080p 24 25 30 P P 3840x2160p 24 25 30 P P 4096x2160p 24 P P 4096x2160p 50 60 4 2 0 P P Cable Specifications CABLE TYPE CABLE LENGTH SUPPORTED VIDEO FORMAT CAT5e...

Page 26: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 27: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 28: ...tate of Texas United States of America A NeuVideo makes no representation that materials pertaining to the Product are appropriate or available for use in other locations other than the shipping addre...

Reviews: