Miracle SteaMer
10
P/N 1010455 Rev. D 03/12
A.J. Antunes & Co.
8. Press and release again and “
h2O
” will be
displayed (figure 6, item g).
9. to change the H2O (steam shot time), press and
release the
prOGram
button again to display
the setting (Figure 6, Item H). Use ▲ or ▼ to
increase or decrease the time.
10. Press the
start/stOp
or
Operate
buttons
to store the changes, exit the PROgRaM Mode,
and initiate the cooking cycle.
impOrtant: 208V and 220/240V miracle steamers
are factory programmed for the following recom-
mended settings:
•
total cycle time (cYc)
= 15 min., 00 secs.
(Range: 3 seconds to 99 minutes 59 seconds)
•
shot interval time (shO)
= 00 min., 20 secs.
(Range: 3 seconds to 5 minutes 59 seconds)
•
steam shot time (h
2
O)
= 0_70
(Range: 0_10 second to 2_50)
this converts approximately 3/4 oz. (25 milliliters) of
water to steam every 20 seconds for a 15 minute cook-
ing cycle.
impOrtant: 120V miracle steamer is factory pro-
grammed for the following recommended settings:
•
total cycle time (cYc)
= 2 min., 00 secs.
(Range: 3 seconds to 99 minutes 59 seconds)
•
shot interval time (shO)
= 00 min., 20 secs.
(Range: 3 seconds to 5 minutes 59 seconds)
•
steam shot time (h2O)
= 0_40
(Range: 0_10 seconds to 2_50)
nOte: the start/stOp or Operate buttons may
be pressed at any time during programming to
store the changes and exit the prOGram mode.
nOte: if a change is not made within 5 seconds
at any time during the programming process, all
changes made up to that point are stored in memory
and the control reverts to the OperatiOn mode.
OperatiOn (continued)
figure 6. control programming sequence
UP
DOWN
PRGM
READY
20
SINGLE SHOT
START/STOP
e. shO time in seconds
UP
DOWN
PRGM
START/STOP
READY
00
SINGLE SHOT
f. shO time in minutes
UP
DOWN
PRGM
START/STOP
READY
1500
SINGLE SHOT
a. total cycle time
UP
DOWN
PRGM
START/STOP
READY
15
SINGLE SHOT
b. total cycle minutes
UP
DOWN
PRGM
START/STOP
READY
H20
SINGLE SHOT
UP
DOWN
PRGM
START/STOP
READY
SINGLE SHOT
G. h2O cycle
h. h2O setting
UP
DOWN
PRGM
START/STOP
READY
00
SINGLE SHOT
UP
DOWN
PRGM
START/STOP
READY
SHO
SINGLE SHOT
c. total cycle seconds
D. shO cycle