Miracle SteaMer
8
P/N 1010455 Rev. D 03/12
A.J. Antunes & Co.
figure 4. connecting water supply
installatiOn (continued)
plumbing
nOte: miracle steamer models are designed to
use cold tap water. Distilled water may be used to
reduce calcium/mineral deposit buildup and reduce
maintenance costs.
these units require a direct cold water hookup. a Water
inlet Hose and strainer assembly (figure 4) is supplied.
nOte: incoming water is controlled by a normally
closed (nc) solenoid valve located inside the
steamer’s electrical housing.
1. turn off the water valve (not supplied) that sup-
plies water to the unit (figure 4).
2. connect the 1/4” (6.5 mm) i.D. flexible tubing to
the outlet side of the Water Pressure Regulator
and secure using the Worm clamp (figure 4).
nOte: a water pressure regulator must first be
installed (figure 4). failure to do so will result
in poor steaming and possible flooding. for a
single steamer, use water pressure regulator p/n
7000314. For two adjacent steamers, use Water
pressure regulator p/n 7000235.
caUtiOn
water pressure must not exceed 30 psi (2.1 kg/cm2
or 207 kpa). higher pressure may cause poor per-
formance or flooding. to reduce water pressure,
install a water pressure regulator, and set to
20–25 psi (1.4–1.7 kg/cm2 or 138–172 kpa).
3. turn the water valve on.
4. Hold the Quick Disconnect insert over a bucket,
then press and hold the white plastic tip until
there’s a good, steady water flow. this will purge
all air out of the line.
5. Release the plastic tip and check the pressure on
the Water Pressure Regulator. it should read
20 psi.
a.) if it reads less, increase the water pressure by
pulling the black knob up and turning it clockwise.
b.) if it reads more, decrease the water pressure
by pulling the black knob up and turning it counter
clockwise.
NOTE: When adjusting the knob, relieve the exist
-
ing pressure by pressing the plastic tip on the
Quick Disconnect insert for 3 seconds. the water
pressure regulator will then show the new pressure.
6. Once the regulator reads 20 psi, push the black
knob down to lock it in place.
7. Push the Quick Disconnect insert into the fitting at
the rear of the unit until it clicks (figure 4).
Connect Quick
Disconnect
Insert Here
Inlet Hose & Strainer
Assy. (Supplied)
Optional Water Pressure Regulator
with Strainer (P/N 7000314)
Shut Off Valve
(Not Supplied)
Cold
Water
Flow
Flexible Nylon Braided
1/4 " I.D. Tubing (Not Supplied)
Quick
Disconnect
Insert
Worm
Clamp
NOTE:
The use of only one strainer is
acceptable instead of two.
caUtiOn
this equipment is to be installed to comply with
the basic plumbing code of the building Officials
and code administrators, inc. (bOca) and the
food service sanitation manual of the food and
Drug administration (fDa).