background image

Miracle SteaMer

20

P/N 1010455 Rev. D 03/12

A.J. Antunes & Co.

1  0011123  solenoid Valve assy. (incl. # 5 & 97)  1

2  7000652 Relay 

1

3  0010584  inlet Hose assy. w/ strainer  

1

5  4040145  solenoid Valve 24 Vac  

6  7000237  top cover assy. (incl. #41 & #42) 

1

7  0011314  steam Vent assy. 

1

8  0021131  floor/chassis Weldment 

1

10  7000246  generator, 230V 

1

 

7000245  generator, 208V 

1

 

7000300  generator, 120V 

1

11  0300129  stud, cover Hold Down 

1

12  040P138*  Locknut, 1/2” 

1

13  040K251  Strain Relief (Incl. #12) 

1

14  05P2199* spacer 

2

15  0503431  Diffuser, steam 

1

17  0503433  cover, generator 

1

18  0503434  cover, end Housing 

1

19  0503435  Retainer, thermocouple 

1

21  0021314  Liner, cavity (Ms-250 only) 

1

21a 0504081  Liner cavity (not shown)  

 

 

for Mfg. No. 9100437 only) 

22  0503441  access cover 

1

23  0503472  bracket, Hi-Limit support 

1

24  0700452  Power cord, NeMa 6-20P 

1

 

0700453  Power cord, cee 7/7 

1

 

0700463  Power cord, Nema 5-15P 

1

26  100P967  Label, Marking 

1

27  1001036  Label, control Panel  

1

28  2000203  tube, Restrictor, 1/4” 

1

29  2000207  tube, inlet, 1/4 x 2-1/2” Long 

1

30  2040103  connector, Male, 1/4 x 1/8 NPt 

32  2040145  elbow, female, 1/8” x 1/4” 

1

33  2040146  tee, female, 1/8” x 1/4” 

1

34  7000694  Water Fitting Kit 

1

 

 

 

(incl. #28, 29, 30, 32, & 33)

35  210K108  Foot, Rubber (4 Pack) 

1

 

36  2100119  Handle, spatula (Ms-250 only) 

1

37  4050180  Heat sink 

1

41  2100249  Guard, Knob 

1

 

42  2100273  Knob 

1

46  7000449  generator tube, 4-1/2” Lg.  

48  300P102*  Nut, speed, “u”, #8-32 

2

49  304P105*  Nut, Hex, KEPS, #4-40, Zinc 

4

50  306P101*  Nut, Hex, #6-32 

2

51  306P105*  screw, Machine, #6-32 x 1/2”  

2

52  306P123*  screw, Machine, #6-32 x 7/8” 

2

53  306P130*  Nut, Hex, KEPS, #6-32 

2

54  306P134*  screw, Machine, #6-32 x 3/8 

3

55  308P103*  screw, Machine, #8-32 x 1/4” 

6

57  308P105*  screw, Machine, #8-32 x 1/2” 

4

58  308P120*  screw, Machine,  

 

 

#8-32 x 5/8” (sltrshd) 

 

59  308P124*  screw, Machine,  

 

 

#8-32 x 1/2” (one-way) 

60  308P143*  Nut, Hex, KEPS, #8-32 

2

61  310P136*  screw, Machine,  

 

 

#10-32 x 1-1/4” (splanhd) 

62  310P149*  screw, Machine,  

 

 

#10-32 x 7/8” 

64  325P170*  Nut, Wing, 1/4-20 

1

65  7000542  Rocker switch, Power On/Off 250V 

1

 

7000543  Rocker switch, Power On/Off 120V 

66  4010166  switch, Momentary (green) 

 

4010190  switch, Momentary (White) 

1

67  7000319  transformer, 115-230/24V 

1

68  7000135  thermostat, Hi-Limit 

1

69  4050214  Thermocouple, Type-K 

1

70  406P107  cable tie 

3

71  7000136  terminal block, 3-Pole 

1

72  7000317  control board,  

 

 

temperature/timer, 24V, 50/60 Hz 

74  338P102*  bolt, Handle Mounting 

    

(Ms-250 only) 

79  0011471  Drawer assy. (incl. #80-87) 

 

 

(Ms-255 only)

80  0021283  Drawer Weldment (Ms-255 only) 

1

81  210K195  Bearing, Roller, SS 

4

 

 

 

(Ms-255 only) (incl. #85) 

82  2100257  Handle (Ms-255 only) 

1

83  2100264  guard, Handle (Ms-255 only) 

1

84  325P132*  screw, Machine, 1/4-20 x 1/2” 

 

 

(Ms-255 only) 

85  05P2991  spacer (Ms-255 only) 

2

86  306P137*  stud, PeM, #6-32 x 3/8”  

 

 

(Ms-255 only) 

87  306P107*  acorn Nut, #6-32 (Ms-255 only) 

2

88  0021237  Liner Weldment (Ms-255 only) 

1

89  0503536  Drip Pan  

1

90  2100118  guard, Handle  

1

91 

See page 21 for Strainer Parts identification.

92  7000139  Quick Disconnect insert 

1

93  0011413  Liner assy. (Ms-255 only) 

1

94  0011370  2” Leg Kit (Incl. #35) 

4

94a 210K134  4” Leg Kit (not shown) 

1

94b 210K123  4” Leg Kit (optional) (not shown) 

1

95  0800359  trivet, spatula (Ms-250 only) 

1

97  7000138  Quick Disconnect Female Kit 

1

 

98  0503429  support, generator upper. 

1

99  7000260  Spatula Kit (Incl. #20, 36, 74, 90, 95)  1

 

 

(Ms-250 only) (9100435/437 Only)

* Only available in quantities of 10.

item  part no. 

Description 

Qty.

item  part no. 

Description 

Qty.

replacement parts (continued)

Summary of Contents for roundup MS-250

Page 1: ...50 255 Owner s Manual P N 1010455 Rev D 03 12 Manufacturing Numbers 9100430 9100435 9100436 9100437 9100438 9100460 9100462 9100466 9100468 A S D L I S T E CM O I N NIT A T C T I S L US E D D L I S T E C US INTERTEK MS 255 Shown ...

Page 2: ... uniform finished product from one operator to the next This manual provides the safety installation and oper ating procedures for the Miracle Steamer We recom mend that all information contained in this manual be read prior to installing and operating the unit Your Miracle Steamer is manufactured from the finest materials available and assembled to Roundup s strict quality standards This unit has...

Page 3: ...r is on the specification plate located on the rear of the unit Purchased From Date of Purchase Model No Serial No Mfg No Refer to the service agency directory and fill in the information below Authorized Service Agency Name Phone No Address Use only genuine Roundup replacement parts in this unit Use of replacement parts other than those sup plied by the manufacturer will void the warranty Your Au...

Page 4: ...e a proper outlet installed by a qualified electrician Do NOT use an extension cord with this appliance Check with a qualified electrician if you are unsure if the unit is properly grounded This equipment is to be installed to com ply with the basic plumbing code of the Building Officials and Code Administrators Inc BOCA and the Food Service Sanitation Manual of the Food and Drug Administration FD...

Page 5: ...100438 230 3300 14 4 50 60 MS 255CV 9100460 208 3300 15 9 50 60 MS 255CF 9100462 120 1800 15 0 50 60 MS 255CV 9100466 230 3300 14 4 50 60 MS 255HC 9100468 230 3300 14 4 50 60 Model and Mfg No Description Configuration MS 250HC 9100438 MS 255HC 9100468 CEE 7 7 16 Amp 250 VAC Assembly Only MS 255CF 9100462 5 15P 15 Amp 120 VAC Non Locking Assembly Only MS 250CV 9100430 9100435 9100436 9100437 MS 255...

Page 6: ...in soap and water Rinse with clean hot water and allow to air dry 5 Wipe all surfaces of the unit with a hot damp cloth NOTE Do NOT use a dripping wet cloth Wring out before use 6 MS 250 Models Assemble the Guard and Mounting Bolt to the Spatula Figure 3 Then install the Wire Trivet into the side slots on the Spatula 7 Re install all removed parts Equipment Setup When placing the unit into service...

Page 7: ... VOIDS ALL WARRANTY PLEASE CHECK YOUR LINE VOLTAGE BEFORE INSERTING THIS PLUG INTO THE RECEPTACLE WARNING WARNING 220 240 VAC ONLY THIS APPLIANCE MUST BE EARTHED GROUNDED THIS APPLIANCE MUST BE EARTHED GROUNDED Electrical 1 Place the unit on a sturdy level table or other work surface 2 Ensure that the line voltage corresponds to the stated voltage on the units specification label and power cord wa...

Page 8: ...Pa 3 Turn the water valve on 4 Hold the Quick Disconnect Insert over a bucket then press and hold the white plastic tip until there s a good steady water flow This will purge all air out of the line 5 Release the plastic tip and check the pressure on the Water Pressure Regulator It should read 20 psi a If it reads less increase the water pressure by pulling the black knob up and turning it clockwi...

Page 9: ... consumed during each water pump activation The amount of steam produced by your Miracle Steamer depends on the amount of water sprayed onto the steam generator Flooding of the generator may occur if the H2O setting is too high To prevent flooding the Shot Interval Time SHO can be increased to allow more time for genera tor heat recovery Adjustments should be made to both values to determine the b...

Page 10: ...mmended settings Total Cycle Time CYC 2 min 00 secs Range 3 seconds to 99 minutes 59 seconds Shot Interval Time SHO 00 min 20 secs Range 3 seconds to 5 minutes 59 seconds Steam Shot Time H2O 0_40 Range 0_10 seconds to 2_50 NOTE The Start Stop or Operate buttons may be pressed at any time during programming to store the changes and exit the PROGRAM Mode NOTE If a change is not made within 5 seconds...

Page 11: ...y When off indicates that the unit is satis fied Green H2O When lit indicates that 24 VAC is being supplied to operate the solenoid valve This LED is only lit for approximately 1 second Fault Codes When the programming parameters for Minutes Seconds SHO H2O have been inadvertently changed below or above their limits the unit displays the ERR fault code Figure 8 If this code appears clear these set...

Page 12: ...ulation of water moisture overnight This could permanently damage of the equipment s finish and its accesso ries This damage is NOT covered by warranty Maintenance Caution Chlorides or phosphates in cleaning agents such as bleach sanitizers degreasers or detergents could cause permanent damage to stainless steel equipment The damage is usually in the form of discoloration dulling of metal surface ...

Page 13: ...or surface Follow the delimer manufac turer s instructions for proper mixture and use Caution If a chemical cleaner delimer is used be sure it is safe to use on cast aluminum Observe all pre cautions and warnings on the product label Maintenance continued NOTE To ensure proper steaming characteristics some calcium mineral deposits must be present on the Generator surface If during cleaning the sur...

Page 14: ...ows 1 Shut off the water supply valve to the unit unscrew the clear plastic Strainer Cup and care fully remove the Mesh Screen 2 At the sink gently flush all of the accumulated debris from the Strainer Cup and Mesh Screen Be especially careful not to damage the Mesh Screen Maintenance continued Mesh Screen O ring 3 Carefully place the Mesh Screen into its seat at the bottom of the Strainer Cup and...

Page 15: ...person or Authorized Service Agency for service Transformer is inoperable Loose burnt or broken wires in circuit Unit does not heat up Control Display is on Hi Limit Thermostat is tripped or inoperable Reset the Hi Limit Thermostat according to the Operations sec tion of this manual If the Hi Limit Thermostat requires continuous resetting contact your Authorized Service Agency for service Solid St...

Page 16: ...am the SHO and H2O values as described in the Programming section of this manual Insufficient or excessive calcium mineral deposits on the Generator surface Verify that thin layer of calcium mineral deposits is present on the Generator surface Refer to the Maintenance section of this manual Generator surface is bare Generator surface must have a thin calcium min eral coating for proper steaming Re...

Page 17: ... letting it rest If the unit still leaks disassemble the Solenoid Valve and clean out the plunger Reassemble unit and test If a leak is still present replace the Solenoid Valve Contact your maintenance person or Authorized Service Agency Solenoid Valve is installed incorrectly If the Solenoid Valve was replaced verify that the IN and OUT labels on the valve corre spond to the water flow There is n...

Page 18: ...18 P N 1010455 Rev D 03 12 A J Antunes Co Replacement parts RE AD Y 64 17 15 18 20 74 36 22 66 65 6 7 8 10 12 13 24 62 94 35 70 57 54 54 54 42 41 89 81 88 93 81 80 85 79 84 83 82 86 87 85 90 95 98 99 74 36 90 95 21 11 ...

Page 19: ...acle steamer 19 P N 1010455 Rev D 03 12 A J Antunes Co READY 22 55 READY 72 49 48 67 50 71 51 57 55 68 69 19 55 25 59 60 27 29 32 33 23 55 28 46 30 5 55 46 37 2 97 READY 26 34 1 Replacement parts continued ...

Page 20: ...e 6 32 x 3 8 3 55 308P103 Screw Machine 8 32 x 1 4 6 57 308P105 Screw Machine 8 32 x 1 2 4 58 308P120 Screw Machine 4 8 32 x 5 8 sltrshd 59 308P124 Screw Machine 1 8 32 x 1 2 one way 60 308P143 Nut Hex KEPS 8 32 2 61 310P136 Screw Machine 4 10 32 x 1 1 4 splanhd 62 310P149 Screw Machine 2 10 32 x 7 8 64 325P170 Nut Wing 1 4 20 1 65 7000542 Rocker Switch Power On Off 250V 1 7000543 Rocker Switch Po...

Page 21: ...g 1 4 I D PVC BRD 24 Long 1 3 2030125 Tubing 1 4 I D PVC BRD 12 Long 1 4 2040150 Elbow Male Nylon 2 1 4 Barb x 3 8 NPT 5 0503615 Bracket Manifold Mtg 1 6 2190129 Nipple 1 4 NPT x 1 4 NPT 1 7 7000333 Strainer 1 4 FPT 1 8 2080118 Quick Disconnect 1 8 NPT 1 9 2190113 Manifold 1 10 211P104 Clamp Ear Med 4 11 2040151 Nipple Hex 3 8 x 1 4 NPT Nylon 1 12 7000306 Gauge Water Pressure 1 13 2170113 Regulato...

Page 22: ... P N 1010455 Rev D 03 12 A J Antunes Co Wiring diagrams NOTE For 208 240 VAC units the two primary coils are wired in series with one another For 120 VAC units the two primary coils are wired in parallel with one another ...

Page 23: ...Miracle steamer 23 P N 1010455 Rev D 03 12 A J Antunes Co Notes ...

Page 24: ...eding maximum weight capacity 4 lbs This warranty does not cover water contamination problems such as foreign material in water lines or inside solenoid valves It does not cover water pressure problems or failures resulting from improper incorrect voltage supply This warranty does not cover Travel Time Mileage in excess of 2 hours 100 miles 160 km round trip from the nearest authorized service age...

Reviews: