background image

EGG STATION (ES-600 & ES-1200)

4

P/N 1010883 08/05 Rev. A 

IMPORTANT SAFETY INFORMATION (continued)

In addition to the warnings and cautions in this manual, 

use the following guidelines for safe operation of the 

unit.

  •  Read all instructions before using equipment.

  •  For your safety, the equipment is furnished with 

a properly grounded cord connector.  Do not 

attempt to defeat the grounded connector.

  •  Install or locate the equipment only for its intend-

ed use as described in this manual.  Do not use 

corrosive chemicals in this equipment.

  •  Do not operate this equipment if it has a dam-

aged cord or plug, if it is not working properly, or 

if it has been damaged or dropped.

  •  This equipment should be serviced by qualified 

personnel only.  Contact the nearest Roundup 

authorized service facility for adjustment or repair.

  •  Do not block or cover any openings on the unit.

  •  Do not immerse cord or plug in water.

  •  Keep cord away from heated surfaces.

  •  Do not allow cord to hang over edge of table or 

counter.

The following warnings and cautions appear 

throughout this manual and should be carefully 

observed.

  •  Turn the unit off, disconnect the power source 

and allow unit to cool down before performing 

any service or maintenance on the unit.

  •  The equipment should be grounded accord-

ing to local electrical codes to prevent the 

possibility of electrical shock.  It requires a 

grounded receptacle with separate electrical 

lines, protected by fuses or circuit breaker of 

the proper rating.

  •  All electrical connections must be in accor-

dance with local electrical codes and any 

other applicable codes.

  •  WARNING ELECTRICAL SHOCK HAZARD.  

FAILURE TO FOLLOW THESE INSTRUCTIONS 

COULD RESULT IN SERIOUS INJURY OR 

DEATH.

-  Electrical ground is required on this appli-

ance.

-  Do not modify the power supply cord plug.  

If it does not fit the outlet, have a proper 

outlet installed by a qualified electrician.

-  Do not use an extension cord with this 

appliance.

-  Check with a qualified electrician if you 

are in doubt as to whether the appliance is 

properly grounded.

  •  If the supply cord is damaged, it must be 

replaced by the manufacturer or its service 

agent.

  •  Do not clean this appliance with a water jet.

  •  Do not use a sanitizing solution or abrasive 

materials. The use of these may cause dam-

age to the stainless steel finish.

  •  Chlorides or phosphates in cleansing agents 

(e.g. bleach, sanitizers, degreasers or deter-

gents) could cause permanent damage to 

stainless steel equipment.  The damage is 

usually in the form of discoloration, dulling 

of metal surface finish, pits, voids, holes or 

cracks.  This damage is permanent and not 

covered by warranty.

•    The following tips are recommended for main-

tenance of your stainless steel equipment,

-  Always use soft, damp cloth for cleaning, 

rinse with clear water and wipe dry.  When 

required, always rub in direction of metal 

polish lines.

-  Routine cleaning should be done daily 

using soap, ammonia detergent and water.

-  Stains and spots should be sponged using 

a vinegar solution as required.

-  Finger marks and smears should be 

rubbed off using soap and water.

-  Hard water spots should be sponged using 

a vinegar solution.

Summary of Contents for roundup ES-600

Page 1: ...P N 1010883 08 05 Rev A EGG STATION Model ES 600 ES 604 ES 1200 Owner s Manual MANUFACTURING NUMBERS 9300530 9300532 9300574 A S D L I S T E CM O I N NIT A T C T I S L US E D ES 600 ES 1200...

Page 2: ...ty OWNER INFORMATION TABLE OF CONTENTS IMPORTANT Keep these instructions for future reference If the unit changes owner ship be sure this manual accompanies the equipment The warranty does not extend...

Page 3: ...h the installation or operation of your unit contact your local Roundup Authorized Service Agency They can be found in the service agency directory packaged with the equipment Fill in the information...

Page 4: ...roper rating All electrical connections must be in accor dance with local electrical codes and any other applicable codes WARNING ELECTRICAL SHOCK HAZARD FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RES...

Page 5: ...VAC Non Locking assembly only Model Number Mfg Number Volts Watts Amp Hertz ES 600CV 9300530 230 2900 12 6 50 60 ES 604CV 9300574 230 2900 12 6 50 60 ES 1200CV 9300532 230 2900 12 6 50 60 WARNING ELEC...

Page 6: ...READY COOKING BACON 1 2 7 9 32 16 5 8 422 mm 185 mm 462 mm 430 mm 157 mm 227 mm 6 3 16 8 15 16 16 15 16 18 3 16 Net Weight ES 600 41 lbs 18 6 kg ES 604 ES 1200 43 lbs 19 5 kg SPECIFICATIONS continued...

Page 7: ...f the unit with a hot damp cloth NOTE Do not use a dripping wet cloth Wring it out before use 5 Clean the Egg Rings Egg Rack cover and ser vice pans in hot soapy water Rinse in clear water and allow t...

Page 8: ...2 Figure 1 Operating Controls Figure 2 Cover Assembly 12 and 6 Egg START STOP POWER 2 00 2 30 READY COOKING BACON 1 2 3 Break the egg yolks if desired 4 Close the cover 5 Fill the trough Figure 2 on t...

Page 9: ...soap and water Hard water spots should be sponged using a vinegar solution CAUTION Do not use a sanitizing solution or abrasive mate rials The use of these may cause damage to the stainless steel fin...

Page 10: ...g times Time 1 Button 2 minute cooking time Time 2 Button 2 minutes and 30 seconds cooking time Checking Cycle Times Monthly CAUTION Grill surfaces will be hot Care should be taken when operating this...

Page 11: ...time selector switch to 2 30 when using refrigerated eggs Time selector switch is set for 2 30 eggs overcooked Set time selector switch to 2 00 when using room temperature eggs Incorrect amount of wa...

Page 12: ...oaded into memory To reload defaults turn the unit off press and hold the Time 2 button turn the unit on and release the button The Green LED blinks on and off 2 times pauses for 2 seconds and repeats...

Page 13: ...POWER WHT BLU BLK BRN GRN YEL GRN HEATER NOTE ALL WIRES TO BE 14 GA TFE 200 C 22 GA TFE 200 C UNLESS OTHERWISE SPECIFIED 18 GA TFE 200 C T3 T4 COUPLE THERMO SWITCH BOARD 230VAC 12VAC TRANSFORMER GRN...

Page 14: ...0 14 P N 1010883 08 05 Rev A REPLACEMENT PARTS 18 21 11 3 14 27 18 31 13 28 65 16 25 51 53 59 61 60 24 19 5 55 4 58 14a 27 31 13a 28 65 45 45 48 48 66 54 63 52 62 57 69 2 7 26 29 15 1 12 12a 64 14b 31...

Page 15: ...2 Nut Speed 8 32 U 1 37 306P113 Screw Mach 2 6 32 x 7 8 Sltrshd 38 306P123 Screw Mach 4 6 32 x 5 8 Sltrshd 2 39 306P130 Nut Hex KEPS 6 32 6 40 308P102 Washer Int Tooth 8 1 41 308P104 Scr Mach 1 8 32 x...

Page 16: ...pay travel mileage or any other charges for an authorized service agency to reach the equipment location 2 Roundup reserves the right to make changes in design or add any improvements on any product...