1
Package and operating conditions
Starter Kit contents
The FMod-TCP BOX 2 “Starter kit” should contain:
FMod-TCP BOX 2 device
RS232 DSub cable
DIN 41651 40 lines cable
CD-Rom with dedicated software and Java applet sample
This manual
Please note that the female connector for the power supply is always
provided with the device.
Electrical characteristics
Damage may occur if the device is operated using values beyond those
mentioned below.
Parameter
Conditions/Remarks
Min Typ Max
Unit
Supply voltage (Vdd)
12
24
33
V
Supply current
Internal
100
mA
All outputs and supply pins of
extension connector altogether.
3.7
A
Inputs voltage
-15
28
V
Outputs 1, 2 current
Relays.
1
A
Outputs 1, 2 voltage
Max voltage to GND.
50
V
Outputs 3-14 current
0.15
A
Outputs 15, 16 current
0.3
A
Outputs 3-16 voltage
Vdd-0.5
V
+5V current
Voltage drops if max is exceeded.
0.3
A
Power output current
Voltage drops if max is exceeded.
1
A
Power outputs voltage
Vdd-0.5
V
Operating temperature
0
70
°C
Storage temperature
-40
120
°C
All external pins are protected against destruction by ESD (2kV).
The power supply input is protected against over voltage by a 33V Zener
diode (max 3A for 10ms) and against inverted voltage by a serial Schottky
diode.
Damages to the device due to over or inverted voltage are not covered by
the warranty.