IP ADDRESS
Register Address
Register Name
Function
Read/Write Control
0x12
IPADDRESS
IP network ID
Read/Write
Register Size
Register structure
Unit
4 Bytes
4 x Unsigned Bytes
none
Description:
Network identifier used for TCP/IP and UDP/IP.
The values 255 (0xFF) and 0 (0x00) are reserved for broadcast and network
addresses and should not be used in this register.
Notes:
The module will change for a new IP address only when all of its
communications ports are closed.
Do not forget to use a
SAVEUSERPARAMETERS
command.
Default value:
169.254.5.5
Example:
For the IP=192.168.16.14 (0xC0, 0xA8, 0x10, 0x0E), write 0xC0A8100E to