Managing the Radio | 235
Aprisa SRx User Manual 1.3.0
CURRENT PROTECTION INFORMATION
Switch Control
This parameter shows the status of the switch control i.e. which mechanism is in control of the protection
switch.
Option
Function
Automatic
The protection is automatic and switching will be governed by
normal switching and blocking criteria.
Software Manual Lock
The Software Manual Lock has control of the protection switch.
Hardware Manual Lock
The Hardware Manual Lock has control of the protection switch.
Active Unit
This parameter shows the radio which is currently active (Primary or Secondary).
Switch Count
This parameter shows the number of protection switch-overs since the last radio reboot (volatile).
Automatic Periodic Switch will occur in
If this parameter is visible, the Automatic Periodic Switch feature has been enabled and will show the
period before the next automatic switch-over.