VISIX S-Series Network Camera
|
USER MANUAL v6.0
10385 Westmoor Drive, Suite 210, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
88
Figure 6-50
Log Searching Interface
2.
Set the log search conditions to specify the search, including the Major Type, Minor Type, Start Time and
End Time as shown in Figure 6-50.
3.
Click
to search log files. The matched log files will be displayed on the
Log
interface.
4.
To export the log files, click
Save Log
to save the log files to your computer.
System Service
Steps:
1.
Enter the System Service interface: Configuration > System > Maintenance > System Service
2.
Toggle the checkbox to enable supplement light function if the device supports this function.
3.
Input a number in text field as the upper limit of the remote connection number. E.g. when you specify
the remote connection number as 10, the number cannot exceed 10 live view connections.
Figure 6-51
Live View Connection Settings
4.
Click
button to activate the settings.
SECURITY
Configuring Authentication Security
Purpose:
From this interface, you can specifically secure the stream data of live view.
Steps:
1.
Enter the Authentication interface:
Configuration
>
System
>
Security
>
Authentication
2.
Set the
RTSP Authentication/WEB Authentication
type from the dropdown list. Digest and digest/basic are
selectable.
3.
Click
to save the settings.
Configuring IP Address Filter