VISIX S-Series Network Camera
|
USER MANUAL v6.0
10385 Westmoor Drive, Suite 210, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
84
Figure 6-42
Time Settings
Configuring Time Synchronization by NTP Server
Steps:
(1)
Toggle the radio button to enable the
NTP
function.
(2)
Configure the following settings:
Server Address:
IP address of NTP server.
NTP Port:
Port of NTP server.
Interval:
The time synchronization interval. It can be set from 1 to 10080 minutes.
Figure 6-43
Time Sync by NTP Server
Click
to make sure that the NTP server is connected.
NOTE
: If the camera is connected to a public network, you should use an NTP server that features
time synchronization capability, such as the server at the National Time Center (IP Address:
210.72.145.44). If the camera resides in a customized network, NTP software can be used to establish
a NTP server for time synchronization.
Configuring Time Synchronization Manually
Steps:
(1)
Toggle the
Manual Time Sync
radio button.
(2)
Click
to set the system time from the pop-up calendar.
(3)
Click
to save the settings.
NOTE:
The user can also toggle the
Sync with local time
checkbox to synchronize the time of the
camera with the time of your computer.