- 2 - 

Front panel view 

               

 

IES618                         IES618-2F 

               

 

IES618-3F                     IES618-4F

 

1. DIP switches for default factory   
2. Console port 
3. 2-pin terminal block for relay output   
4. Ground screw 
5. Power input terminal block 
6. Screw holes for Wall Mounting Kit   
7. DIN-Rail mounting kit   
8. Relay alarm LED 
9. Power indicator (PWR1, PWE2) 
10. System running LED   

11. Link/ACT LEDs   
12. 10Base-T /100Base-TX Ethernet port 
13. 100Base-FX fiber port 

Power supply input

 

DC Series Switch:

 

 

The  switch  have redundant power input, provides one terminal 
block (4 bits) for PWR1 and PWR2 input. The redundant power 
can be used single and used two self-governed power to supply to 
the system, PWR1 and PWR2 input at  the same time, when 
neither of these two power fails, the other power acts as a backup, 
and  automatically supplies power needs,  ensure  running  
Ethernet reassuring. Voltage input range is 12

48VDC (terminal 

block defined as: V1-

V1+

V2-

V2+). 

AC Series Switch: 

 

The  Industrial  Ethernet  switches have  singe power and 
redundancy power two kinds of power input. The singe power AC 
series  top  panel provides 3  bit terminal  block  for 
100~240VAC/DC power entered (L/+, FG, N/-) 
Important notice: 
1.

 

Power ON operation: first of all, insert power cable’s terminal 

block into device’s power port, then insert power supply plug into 
power source 
2.

 

Power OFF operation: First off all, unpin power plug, then 

strike the terminal block, please take care of operation sequence. 

Dimension

 

The series of products size is the same, and the type of the 
Ethernet interface is different. Unit (mm)

 

 

 

DIP Switch

 

 

Top panel provided 4 bits DIP switch to do function configure

ON to enable effective

,1 and 4 keep for future function. 2 is 

for upgrade. 3 is  recovery default factory. Please power off and 
power on when you change the status of DIP switch. 

Relay connection

 

 

Relay access terminals in the top panel of the device. Between the 
two terminal relay, as an open circuit state in normal non alarm 
state, when there is any alarm information to the closed state. The 
two terminal block connector are used to detect both power failure 
and port failure. The

 

two wires attached to the Fault contacts form 

an open circuit when the device has lost power supply from one of 
the DC power inputs or one of the ports is failure. (Note: The AC 
power switch does not support power alarm.) 

Summary of Contents for IES618-P

Page 1: ...ment requirement It can use in power water conservancy transportation area etc Packing list The industrial Ethernet switch is shipped with the following items If any of these items are missing or damaged please contact your customer service representative for assistance Industrial Ethernet switch ⅹ 1 Documentation and software CD ⅹ 1 User manual ⅹ 1 DIN Rail mounting kit ⅹ 1 Warranty card ⅹ 1 Feat...

Page 2: ...l provides 3 bit terminal block for 100 240VAC DC power entered L FG N Important notice 1 Power ON operation first of all insert power cable s terminal block into device s power port then insert power supply plug into power source 2 Power OFF operation First off all unpin power plug then strike the terminal block please take care of operation sequence Dimension The series of products size is the s...

Page 3: ...port RX receive port connect remote switch s TX transmit port The optical fiber connection supports the line to instruct enhance the reliability of network effectively Suppose If you make your own cable we suggest labeling the two sides of the same line with the same letter A to A and B to B shown as below or A1 to A2 and B1 to B2 LED Indicator LED indictor light on the front panel of product the ...

Page 4: ...nment rack 8 Pigtail cannot be tied and swerved as less as possible Swerving radius cannot be too small small swerving causes terrible loss of link Its banding should be moderate not too tight and should be separated from other cables 9 It should have corresponding simple signal at both sides of the cable for maintaining Specification Technology Standard Support IEEE802 3 IEEE802 3u IEEE 802 3x IE...

Page 5: ...8VDC Unload consumption 4 9W 12VDC Full load consumption 6 4W 12VDC IES618 4F P 220VAC Unload consumption 5 0W 220VAC Full load consumption 6 1W 220VAC Working environment Working temperature 40 75 Storage temperature 40 85 Relative Humidity 5 95 no condensation Mechanical Structure Shell IP40 protect grade metal shell Installation DIN Rail mounting Weight 808g Size W H D 53mm 138mm 110mm Industry...

Reviews: