Console port

 

This series product provided 1pcs procedure test port based in 
serial port. It adopts RJ45 interface, located in top panel, can 
configure related command through RJ45 to DB9 female cable. 

 

Communication connector

 

10/100BaseT(X) Ethernet port 

The pinout define of RJ45 port display as below, connect by UTP 
or STP. The connect distance is no more than 100m. 100Mbps is 
used 120

Ω

 of UTP 5, 10Mbps is used 120

Ω

 of UTP 3, 4, 5. 

 

RJ 45 port support automatic MDI/MDI-X operation. can connect 
the PC, Server, Converter and HUB .Pin 1,2,3,6 Corresponding 

connection  in  MDI.  1→3,

 

2→6,

 

3→1,

 

6→2  are  used  as  cross 

wiring in the MDI-X port of Converter and HUB. 
10Base-T/100Base-TX are used in MDI/MDI-X, the define of Pin 
in the table as below. 

NO. 

MDI signal  MDI-X signal 

TX+ 

RX+ 

TX- 

RX- 

RX+ 

TX+ 

RX- 

TX- 

4, 5, 7, 8 

 

 

Note

TX

±”

Transmit Data

±,

RX

±”

Receive Data

±,

—”

  Not use.

 

10/100Base-T(X) MDI (straight-through cable) 

 

10/100Base-T(X) MDI-X (Cross over cable) 

 

MDI/MDI-X  auto connection makes switch easy to use for 
customers without considering the type of network cable. 

100Base-FX Fiber port   

100Base-FX full-duplex SM or MM port, SC/ST/FC  type .The 
fiber port must be used in pair, TX (transmit) port connect remote 
switch’s RX(receive) port; RX(receive) port connect remote 
switch’s TX(transmit) port. 
The optical fiber connection supports the line to instruct enhance 
the reliability of network effectively. 

Suppose

:  If you make your own cable, we suggest  labeling  the 

two sides of the same line with the same letter (A-to-A and B-to-B, 
shown as below, or A1-to-A2 and B1-to-B2). 
 

 

LED Indicator

 

LED indictor light on the front panel of product, the function of 
each LED is described in the table as below. 

System indication LED 

LED 

State 

Description 

PWR 
(1~2) 

ON 

Power is being supplied to power 
input PWR 

OFF 

Power is 

not 

being supplied to 

power input PWR 

Alarm 

ON 

When the alarm is enabled, power 
or the port’s link is inactive. 

OFF 

Power and the port’s link is active, 
the alarm is disabled. 

Run 

ON/OFF  System is not running well 

Blinking  System is running well 

Link/ACT 
(1~8) 

ON 

Port connection is active 

Blinking  Data transmitted 

OFF 

Port connection is not active 

Installation

 

Before installation, confirm that the work environment meet the 
installation require, including the power needs and abundant 
space. Whether it is close to the connection equipment and other 
equipments are prepared or not.   
1. Avoid in the sunshine, keep away from the heat fountainhead or 

the area where in intense EMI. 

2. Examine the cables and plugs that installation requirements. 
3. Examine whether the cables be seemly or not (less than 100m) 

according to reasonable scheme.   

1

8

Summary of Contents for IES618-P

Page 1: ...ment requirement It can use in power water conservancy transportation area etc Packing list The industrial Ethernet switch is shipped with the following items If any of these items are missing or damaged please contact your customer service representative for assistance Industrial Ethernet switch ⅹ 1 Documentation and software CD ⅹ 1 User manual ⅹ 1 DIN Rail mounting kit ⅹ 1 Warranty card ⅹ 1 Feat...

Page 2: ...l provides 3 bit terminal block for 100 240VAC DC power entered L FG N Important notice 1 Power ON operation first of all insert power cable s terminal block into device s power port then insert power supply plug into power source 2 Power OFF operation First off all unpin power plug then strike the terminal block please take care of operation sequence Dimension The series of products size is the s...

Page 3: ...port RX receive port connect remote switch s TX transmit port The optical fiber connection supports the line to instruct enhance the reliability of network effectively Suppose If you make your own cable we suggest labeling the two sides of the same line with the same letter A to A and B to B shown as below or A1 to A2 and B1 to B2 LED Indicator LED indictor light on the front panel of product the ...

Page 4: ...nment rack 8 Pigtail cannot be tied and swerved as less as possible Swerving radius cannot be too small small swerving causes terrible loss of link Its banding should be moderate not too tight and should be separated from other cables 9 It should have corresponding simple signal at both sides of the cable for maintaining Specification Technology Standard Support IEEE802 3 IEEE802 3u IEEE 802 3x IE...

Page 5: ...8VDC Unload consumption 4 9W 12VDC Full load consumption 6 4W 12VDC IES618 4F P 220VAC Unload consumption 5 0W 220VAC Full load consumption 6 1W 220VAC Working environment Working temperature 40 75 Storage temperature 40 85 Relative Humidity 5 95 no condensation Mechanical Structure Shell IP40 protect grade metal shell Installation DIN Rail mounting Weight 808g Size W H D 53mm 138mm 110mm Industry...