Managed Industrial Ethernet Switch User Manual
3onedata proprietary and confidential 55
Copyright © 3onedata Co., Ltd.
Operation Steps
Configure switch A and switch B in the same way respectively.
Log in Web configuration page.
Choose “Main Menu > Redundancy > Port Trunking > Static Trunking”.
On the page of “Static Trunking”, check the box of “Yes” in the “Enable” bar.
Choose “1” in the droplist of “Group”.
Check the box of Port 1 and Port 2 in the “join port” bar.
Click “Add/Edit”.
Click “Apply”.
End.
⚫
All attributes of ports in trunking group should be the same, including rates and duplex
modes, etc.
⚫
Setting one port as both ring network port and trunking port is not supported.
⚫
Each trunking group should have 2 ports at least, up to 4.
⚫
One port can only join a trunking group.