Managed Industrial Ethernet Switch User Manual
3onedata proprietary and confidential 16
Copyright © 3onedata Co., Ltd.
Interface Element
Description
Target Port
1-65535, it refers to the TCP port number connected
to CAN server.
Connect Mode
⚫
Connect now: The device will be connected after
being powered on; and it will be reconnected
after being disconnected.
⚫
Data Trigger: CAN server initiates connection
when the corresponding CAN port of the device
receives data.
AT
0-65535s, the device sends out heartbeat packet
after the setting time interval, and the session will be
disconnected if there is no reply for three
consecutive times.
Discon Timeout
0-65535s, configure the idle time of automatic
disconnection. The device will disconnect the
session if there is no data transmission in the setting
time. If it
is configured as “0”, the device won’t
forwardly disconnect the session no matter how long
the idle time is.
Interface Description: Advanced Mode
The interface of TCP Server under the advanced mode as follows:
UDP interface under the advanced mode as follows: