background image

 

 

 

 

 

 

IEM615 SeriesManaged 
Industrial Ethernet Switch Module 

User Manual 

Version  02 

Issue Date: 2018-12-20 

 
 
 
 
 

Industrial Ethernet Communication Solutions Expert                                                              3onedata Co., Ltd. 

Summary of Contents for IEM615 Series

Page 1: ...IEM615 SeriesManaged Industrial Ethernet Switch Module User Manual Version 02 Issue Date 2018 12 20 Industrial Ethernet Communication Solutions Expert 3onedata Co Ltd...

Page 2: ...product service or features should be constrained by 3ondedata commercial contracts and clauses The whole or part product service or features described in this document may beyond purchasing or using...

Page 3: ...aiwangxin High Technology Industrial Park Song Bai Road Nanshan District Shenzhen 518108 China Technology support tech support 3onedata com Service hotline 86 400 880 4496 E mail sales 3onedata com Fa...

Page 4: ...suits for engineers as follows Network administrator responsible for network configuration and maintenance On site technical support and maintenance staff Hardware engineer Text Format Convention For...

Page 5: ...e notes on the mark improper operation may cause personal injury Make a necessary supplementary instruction for operation description Configuration operation or tips for device usage Pay attention to...

Page 6: ...L SERVER 7 3 1 COM SETTINGS 7 3 2 SERIAL PORT INFORMATION 11 4 CAN SERVER 13 4 1 CAN CONFIGURATION 13 4 2 CAN INFORMATION 17 5 PORT CONFIGURATION 19 5 1 PORT SETTING 19 5 2 BANDWIDTH MANAGEMENT 21 6 L...

Page 7: ...56 9 1 LOGIN SETTINGS 56 10 REMOTE MONITORING 58 10 1 SNMP CONFIGURATION 58 10 2 SNMP CONFIGURATION 60 10 3 RELAY WARNING 63 11 PORT STATISTICS 66 11 1 FRAME STATISTICS 66 12 NETWORK DIAGNOSIS 71 12 1...

Page 8: ...ystem should meet the following conditions Hardware and Software System Requirements CPU Above Pentium 586 Memory Above 128MB Resolution Above 1024x768 Color Above 256 color Browser Above Internet Exp...

Page 9: ...tes While first configuring the switch if it is a local configuration mode please make sure that the network segment of current PC is 1 E g Assume that the IP address of the current PC is 192 168 5 60...

Page 10: ...please strictly distinguish capital and small letter while entering Default username and password have the administrator privileges WebServer will provide 3 times opportunities to enter username and p...

Page 11: ...Managed Industrial Ethernet Switch User Manual 3onedata proprietary and confidential 4 Copyright 3onedata Co Ltd After login in the device modify the switch IP address for usage convenience...

Page 12: ...ht 3onedata Co Ltd 2System Configuration 2 1 System Information Function Description In System Information page user can check Device Information and Port Info Operation Path Open in order Main Menu S...

Page 13: ...urrent using software version information updated software version has more functions MAC Address Hardware address of device factory configuration Contact Information Display the contact information o...

Page 14: ...ngs Function Description On the page of COM Settings user can configure baud rate data bit stop bit parity bit and other basic parameters information of corresponding serial number and the operating m...

Page 15: ...serial number selection Serial No Select corresponding serial number of the device Serial Parameter Settings Serial parameter settings column Baud Rate bps Select baud rate of corresponding serial nu...

Page 16: ...l data to Ethernet data value range is 1 500ms COM Mode It s decided by software and hardware there are RS232 RS485 RS422 three modes Work Mode Settings Work Mode Settings Column Mode Setting Optional...

Page 17: ...me of automatic disconnection and the serial server will break the session connection if there is no data transmission within given time If it s set to 0 the serial server won t positively break the c...

Page 18: ...ress of address pool needs to be in the same network segment The start address value of address pool must be less than or equal to its end address value 3 2 Serial Port Information Operation Path Open...

Page 19: ...Serial NO Serial number configuration column Operation Pull down list of serial port Statistics information Statistics information column COM Send Error Quantity statistics of error bytes sent out by...

Page 20: ...the page of CAN Configuration user can configure the parameters information of corresponding CAN port such as session number TCP operating mode operating port baud rate operating mode of CAN server de...

Page 21: ...CAN port number of the device CAN Parameters Settings Configuration column of CAN parameters Baud Rate Select the baud rate of corresponding CAN port number Options include 5K 10K 20K 30K 40K 50K 80K...

Page 22: ...on between TCP client and server is established TCP Trubo Enabling TCP Turbo means that the number of subpackage frames is configured as 1 Work Mode Settings Configuration column of operating mode Mod...

Page 23: ...rt of the device receives data AT 0 65535s the device sends out heartbeat packet after the setting time interval and the session will be disconnected if there is no reply for three consecutive times D...

Page 24: ...art address of address pool can t be larger than the one of the end address of address pool 4 2 CAN Information Function Description On the page of CAN Information user can check and count the error i...

Page 25: ...list and select the corresponding port number of CAN server Statistics Information Statistics Information Column CAN Send Error Count the error information transmitted by CAN server CAN BUS Error Coun...

Page 26: ...can check port type rate and connection state set rate mode duplex mode port enable flow control and other parameters Speed duplex flow control will take effect when the port is enabled After selectin...

Page 27: ...0M Half duplex 100M Auto Detect Notes All copper ports of the switch are MDI MDIX self adapting ports and support automated negotiation speed mode Duplex Click the drop down list box of Duplex to sele...

Page 28: ...the ingress and egress bandwidth speed of the port Operation Path Open in order Main Menu Port Configuration Bandwidth Management Interface Description Bandwidth management interface as below The mai...

Page 29: ...ion area click the option box of Enable In Egress area choose 4M as the egress speed of Port 1 In Ingress area choose 4M as the ingress speed of Port 1 Click Apply End Flow control should be enabled w...

Page 30: ...wing benefits to users Limit the broadcast domain Increase the security of LAN Improve the network stability Flexiblely construct virtual working team Port VLAN Port VLAN adopts different identificati...

Page 31: ...ity CFI Canonical Format Indicator represents whether MAC address is packaged in standard format in different transmission media 0 represents that MAC address is packaged in standard format VID VLAN I...

Page 32: ...guration information Instance create port based VLAN The steps of configuring port based VLAN Open Main Menu L2 Feature VLAN On the option box of VLAN Mode select Port based VLAN Enter VLAN table item...

Page 33: ...ame control Choose VLAN tag replace configuration options are No need change VID Replace VID into default VID Default VID The configuration bar of default VID 802 1Q VID VLAN ID number Its value range...

Page 34: ...ut port 3 and Port 4 can t communicate with each other as the picture below Do not consider other ports how to set the VLAN Example Analysis Configure the Type of Port3 Port4 and Port5 as Access Port3...

Page 35: ...ng entry analysis of Port 3 Port 4 and Port 5 forwarding entry design picture as follows Operation Steps Enter Main Menu Layer 2 Config VLAN Choose IEEE 802 1Q VLAN in the option box of VLAN mode Choo...

Page 36: ...ber list Enter 5 in 802 1Q VID textbox In the drop down list of member type 1 Set the member type of Port3 to U 2 Set the member type of Port4 to U 3 Set the member type of Port5 to U Click Add edit b...

Page 37: ...ace Interface Element Description IGMP snooping The switch of IGMP snooping function options are Enable Disable Notes IGMP snooping means snooping the messages between user host and router as well as...

Page 38: ...list of static multicast Operation Path Open in order Main Menu L2 Feature Multicast Configuration Interface Description Static filtering interface as follows Main elements configuration description o...

Page 39: ...or protocol please don t use them IGMP dynamic learning won t update statically typed multicast address static multicast forwarding table is more of a security mechanism Example Static Multicast Filte...

Page 40: ...ht 3onedata Co Ltd 7QoS 7 1 QoS Classification Function Description On the page of QoS Classification user can set Queuing mechanism Enable ToS Enable CoS Port priority Operation Path Open in order Ma...

Page 41: ...es and schedules in the decreasing order of priority When the queue with fairly high priority is empty then it would send groupings of queue with fairly low priority Port Port number of switch Inspect...

Page 42: ...S values are the same queuing according to CoS priority Instance QoS configuration For example Set port 1 s queuing mechanism as Weight Fair 8 4 2 1 adopts ToS priority Operation steps Open Main Menu...

Page 43: ...nding priority queue is Low When the CoS value is set to 2 and 3 the corresponding priority queue is Normal When the CoS value is set to 4 and 5 the corresponding priority queue is Medium When the CoS...

Page 44: ...the CoS value is 6 choose High as the corresponding priority 8 When the CoS value is 7 choose High as the corresponding priority Click apply Ends 7 3 ToS Mapping Function Description On the page of C...

Page 45: ...on For example When the ToS value is set to 0x00 0x3C the corresponding priority is Low When the ToS value is set to 0x40 0x7C the corresponding priority is Normal When the ToS value is set to 0x80 0x...

Page 46: ...cription On the Rapid ring page user can choose redundancy protocol and configure the ring network under this protocol quickly Operation Path Open in order Main Menu Redundancy Rapid Ring Interface De...

Page 47: ...sabled Ring V3 single ring coupling ring chain and Dual homing are supported RSTP IEEE 802 1W 1D rapid spanning tree Function description of Ring V1 V2 V3 On the rapid ring page user can choose Ring r...

Page 48: ...on of two rings Type According to the requirement in the scene user can choose different ring network Single single ring using a continuous ring to connect all device together Couple couple ring is a...

Page 49: ...Device 100 101 and 102 are port 1 and port 2 Therefore creating single ring is viable Port 1 and port 2 are set as the ring ports of each device Operation steps Configuring Device 100 101 and 102 in...

Page 50: ...separately Note Port 1 and Port 2 cannot be set to the same port Click Apply Enter Main Menu System Management Device Address In the area of reboot the device click reboot End 8 1 2Instance create cou...

Page 51: ...07 108 and 109 are in Ring 1 ring network ports are Port 1 and Port 2 single ring 105 is the master station others are slave stations 100 101 102 103 and 104 are in Ring 2 ring network ports are Port...

Page 52: ...Click Apply Enter Main Menu System Management Device Address In the area of reboot the device click reboot End Operation Step 2 configuring Ring 2 in WEB interface Configuring Device 100 101 102 103...

Page 53: ...vice Address In the area of reboot the device click reboot End Operation Step 3 configuring Ring 3 in WEB interface Configuring Device 100 101 105 and 106 in the following steps respectively Choose Ma...

Page 54: ...tocol of Redundancy is Ring V3 Instance For example creating chain Its basic architecture is shown as below Instance analysis Basic framework we can make the following analyses 100 101 102 103 and 104...

Page 55: ...nfiguring Device 100 101 102 and 103 in the following steps respectively Choose Main Menu Redundancy Rapid Ring In the Settings area of Rapid Ring page choose Ring V3 as Protocol of Redundancy Check t...

Page 56: ...Ring In the Settings area of Rapid Ring page choose Ring V3 as Protocol of Redundancy Check the Enable box in the Group 1 In the Settings area of Rapid Ring page set the Type to Chain In the Settings...

Page 57: ...at have already been set as ring network to Trunk and member relationship to Tagged When forming complicated ring networks like tangent ring please make sure the ID conforms to the unity of single rin...

Page 58: ...the port of switch maintains in transition state listening and learning Note STP RSTP adopts a mechanism of state transition The newly selected root port and specified port have to go through twice t...

Page 59: ...tion of RSTP status interface Interface Element Description Root information The display bar of root information table Local ID It displays the priority of this switch and MAC address information ID R...

Page 60: ...cted switch port Edge The port that directly connects to terminal instead of other switches Connected It displays the network protocol of devices with connected ports Role Root port specified port Alt...

Page 61: ...Trunking interface as follows The main element configuration description of static trunking interface Interface Element Description Enable Enable or disable trunking configuration Group Choose trunki...

Page 62: ...runking On the page of Static Trunking check the box of Yes in the Enable bar Choose 1 in the droplist of Group Check the box of Port 1 and Port 2 in the join port bar Click Add Edit Click Apply End A...

Page 63: ...Control 9 1 Login Settings Function Description On the Login Settings page user can configure the login name and password of logging in to WEB configuration page and other parameter information Opera...

Page 64: ...configuration interface Note The password should a combination of letters that less than 16 bytes Confirm password Confirm password Please keep the modified login name and password in mind If you forg...

Page 65: ...he page of SNMP Configuration user can conduct the following operations Enable or disable SNMP configuration function Configure SNMP V1 V2 read only community name Configure SNMP V1 V2 read only commu...

Page 66: ...an be used widely but exists security issue SNMP V2 Semantics has been enhanced and it supports TCP protocol SNMP Read Community Configure the read only SNMP community name with the only operation per...

Page 67: ...Configuration On the displayed page of SNMP Configuration 1 Select enable on the column of SNMP Configuration 2 Select Read only community name as public 3 Select Read Write community name as private...

Page 68: ...nction options as follows Enable Disable SNMP V1 V2 SNMP supports the following version SNMP V1 It adopts UDP protocol which can be used widely but exists security issue SNMP V2 Semantics has been enh...

Page 69: ...ng cold or warm start port offline online power on off Please pay attention to the permission problem of read and write in the SNMP browser user can check the permission of used community name if the...

Page 70: ...strator and quickly repair the equipment status to avoid excessive losses Operation Path Open in order Main Menu Remote Monitoring Relay Warning Interface Description Relay warning interface as follow...

Page 71: ...onfigure the power supply alarm function Options as follows Enable Disable Status Display current status of power supply Fault Normal Port Events Port events column Port Display the device port number...

Page 72: ...in Menu Remote Monitoring Relay Warning On the displayed page of Relay Warning 1 Select enable on the column of Alarm Setting 2 Select Relay Output Type as open On the region of System Events select E...

Page 73: ...stics 11 1 Frame Statistics Function Description On the page of Frame Statistics user can check frame statistics of sending receiving data packets transmitted by the port within a period of time Opera...

Page 74: ...ansmitted by a port excluding preamble but including FCS TxDropPkts This counter is incremented every time a transmit packet is dropped due to lack of resources TxBroadcastPkts The number of good pack...

Page 75: ...the medium is busy This only applies to the Half Duplex mode while the Carrier Sensor Busy TxLateCollision The number of times that a collision is detected later than 512 bit times into the transmiss...

Page 76: ...ize inclusive RxOversizePkts The number of good packets received by a port that are greater than 1522 bytes tagged and 1518 bytes untagged RxJabbers The number of packets received by a port that are l...

Page 77: ...rror or an alignment error JumboPkt The number of good packets received by a port that are greater than the standard maximum size and less than or equal to the jumbo packet size regardless of CRC or a...

Page 78: ...1 Port Mirror Function Description On the Port Mirror page user can enable or configure the correspondence between ingress data mirror and egress data mirror Operation Path Open in order Main Menu Di...

Page 79: ...ingress egress data mirroring Watch direction Backup data during mirroring options are All Ingress Egress For instance port mirror configuration For example use port 4 to collect ingress data and egre...

Page 80: ...dress Function Description On the page of Network Settings user can conduct following operations Configure default IP address of the device Configure netmask Configure gateway address Configure DNS se...

Page 81: ...ce IP address IP Address Configure IP address of the device Notes Default configured IP address is 192 168 1 254 Subnet Mask Configure subnet mask of the device Notes Default configured subnet mask is...

Page 82: ...eboot Step 3 On the Network Settings region of displayed page of Device Management select Use the following IP address a Enter 192 168 5 88 in the textbox of IP Address b Enter 192 168 5 1 in the text...

Page 83: ...f system information interface Interface Elements Description Module Configure the device model Name Configure the device name to identify each device in the network Description Configure the device s...

Page 84: ...interface Step 2 Select Main Menu Basic Settings System Identification Step 3 On the Settings region of displayed page of System Identification a Enter Module as ManagedSwitch1 b Enter Name as Indust...

Page 85: ...status to be in the factory status default IP address is 192 168 1 254 Update Configuration File from Local PC Configuration column of configuration files Download Configuration Download the configur...

Page 86: ...Management click Download Click Save S on the pop up dialog box of File Download Select save path on the pop up dialog box of Save as Click Apply End Example Upload Configuration For example Upload c...

Page 87: ...rrent user For example Log off and change administrator to login For example Log off current user and then login again via entering admin8 in the column of administrator and admin8 in the column of pa...

Page 88: ...forgetting the login password the password can be initialized by restoring factory setting specific method is adopt BlueEyes_ software to search and use restore factory setting function to initialize...

Page 89: ...ch port faults User can locate the faults via following tests Connected computer and switch ports keep invariant change other network cable Connected network cable and switch port keep invariant chang...

Page 90: ...eshooting connect the network cable again Ethernet terminal device or network card works abnormally troubleshooting eliminate the terminal device fault Not connected to the power socket troubleshootin...

Page 91: ...line or shields the interference source Site wiring is not normative Troubleshooting optical fiber network cable optical cable cannot be arranged with power line and high voltage line Network cable i...

Page 92: ...ata Co Ltd 3onedata Co Ltd Headquarter address 3 B Zone 1 Baiwangxin High Technology Industrial Park Song Bai Road Nanshan District Shenzhen Technology support tech support 3onedata com Service hotlin...

Reviews: