background image

                                          

Shenzhen

 

3onedata Technology Co., Ltd 

1                                        

www.3onedata.com

 

Chapter 1 Summarize 

1.1 Introduction 

CAN485  is used for data exchange between CAN-Bus  field bus and RS-485  bus interface converter, and 

supports Modbus RTU protocol. CAN485 interface converter integrated a RS-485 channel and a CAN-Bus channel 

can be easily embedded using RS-485  interface for communication nodes, do not need to change the original 

hardware architecture enables the device to obtain the CAN-Bus communication interface, to achieve between the 

equipments of RS-485 and CAN-Bus  network connection and data communication. RS-485 channel CAN485 

devices to support a variety of baud rate, the range is 300bps~115200bps. CAN-Bus  channel support CiA 

recommended a variety of standard baud rate and user-defined baud rate, the range of 2.5Kbps~1Mbps. CAN485 

interface converter provides three types of data conversion: transparent conversion, encryption conversion and 

Modbus protocol conversion. 

Its exterior design supports DIN-Rail mounting and Wall mounting, which is convenient for engineering 

application. The board comes with a photoelectric isolation module, complete electrical isolation control circuit and 

CAN-Bus  communication circuit, so that the CAN485 converter has a strong anti-interference ability, greatly 

improving the system in the harsh environment of the use of reliability. 

 

1.2 Product Features 

 

Support CAN2.0A and CAN2.0B protocol, in compliance with the ISO/DIS 11898 specification 

 

Bidirectional data communication between CAN-Bus and RS-485 

 

Integrated 1 CAN-Bus communication interface, support for user-defined baud rate 

 

Integrated 1 RS-485 three pins type communication interface, communication rate between 300~115200bps 

can be set 

 

Provide three kinds of data conversion modes: transparent conversion, transparent with the identity conversion, 

Modbus protocol conversion 

 

CAN-Bus circuit using 2000V AC electrical isolation, support 8KV electrostatic protection (air discharge)   

 

CAN-Bus baud rate 2.5k~1Mbps 

 

Maximum frame rate: 500 frames per second 

 

DC9~48V wide voltage supply input, power supply support reverse connection 

 

IP40 protection grade, DIN-Rail or wall mounting installation 

 

-40-

75℃  working temperature

 

 
 
 
 
 
 
 

Summary of Contents for CAN485

Page 1: ...Shenzhen 3onedata Technology Co Ltd CAN485 Interface Converter User Manual Version 1 0 0 Feb 2016 Shenzhen 3onedata Technology Co Ltd www 3onedata com...

Page 2: ...ks in this manual belong to their respective manufacturers Agreement As the product version upgrades or other reasons this document is subject to change without notice Unless other agreement this docu...

Page 3: ...configuration 10 5 2 Introduction of Software 10 5 2 1 Conversion parameter 11 5 2 2 COM parameter 13 5 2 3 CAN Bus parameter 13 5 2 4 Keys description 14 Chapter 6 Application Description 15 6 1 Tran...

Page 4: ...mounting and Wall mounting which is convenient for engineering application The board comes with a photoelectric isolation module complete electrical isolation control circuit and CAN Bus communication...

Page 5: ...ply Input voltage 9 48VDC Type of input 2 bits terminal block No load consumption 1 57W 9VDC Full load consumption 1 59W 9VDC Power support reverse connection Working environment Working temperature 4...

Page 6: ...Shenzhen 3onedata Technology Co Ltd 3 www 3onedata com Chapter 2 Hardware Description 2 1 Interface Description Top view Front and Rear view Side view...

Page 7: ...iption 2 2 1 Power Input CAN485 interface converter provide DC power input voltage input is the two terminal form plug type 2 core spacing of 5 08mm terminals wherein the power input range of 9 48VDC...

Page 8: ...to short circuit between the twisted pair ports RES and RES to achieve terminal resistor accession as shown below When the CAN485 converter is used as the CAN Bus network terminal the two pin is conn...

Page 9: ...Requirements Cable laying need to meet the following requirements 1 It is needed to check whether the type quantity and specification of cable match the requirement before cable lying 2 It is needed t...

Page 10: ...swerved as less as possible Swerving radius cannot be too small small swerving causes terrible loss of link Its banding should be moderate not too tight and should be separated from other cables 9 It...

Page 11: ...Shenzhen 3onedata Technology Co Ltd 8 www 3onedata com Chapter 3 Appearance and Dimension Appearance CAN485 Dimension Unit mm...

Page 12: ...ing List The first time use this product please check the packaging is intact or not and the attachment is complete or not at first Item Quality Interface Converter 1pcs User manual 1pcs Documentation...

Page 13: ...the DIP switch that RS 485 interface side of the DIP switch pin 2 Pin 2 is allocated to ON enable end the converter enter configuration mode Pin 2 is allocated to number end the converter power on in...

Page 14: ...on the bus Allow the CAN Bus frame information forwarded to the serial frame This parameter is used only in the transparent conversion mode when selected converter work will add CAN Bus message frame...

Page 15: ...to send a single character as the unit of time Here you can set the 2 10 character of the optional time The serial number of characters frame interval can be set only with the identity transformation...

Page 16: ...0bps Serial parity none even and odd marks spaces and stop these 6 options No matter what kind of check mode converter serial transmission of data bits is 8 No parity only add 1 start bit and 1 stop b...

Page 17: ...9 so the maximum filtering acceptance code 0x1F FF FF FF the invalid part of more than 29 bit identifier software only low 29 bit identifier Filter mask off code HEX Fill in the data format is 16 hexa...

Page 18: ...me If the converter detects the serial bus data immediately received and converted CAN Bus message frame information and frame ID is user pre configured keep these parameters in the serial CAN Bus mes...

Page 19: ...essage ID frame to fill all the bytes of serial frame 6 1 3 Conversion example 1 Serial frames conversion CAN Bus message The hypothetical configuration into CAN Bus message frame information for stan...

Page 20: ...N Bus parameters to send invalid identifier because the identifier transmitted ID frame filled by serial data in the frame 6 2 1 Frame format Serial bus frame With the identity transformation must obt...

Page 21: ...ID to continue converting serial frame until the conversion is complete 2 CAN Bus message to serial frame For the CAN Bus message immediately received a frame forwarding a frame when forwarding accord...

Page 22: ...Data 4 Data 5 Data 6 Data 7 Serial frame Data 1 Data 2 Data 3 Frame ID 1 Data 4 Data 5 Data 6 Data 7 Serial frame Address 0 Data 1 Address 1 Data 2 Address 2 Data 3 CAN ID1 Address 3 Data 4 CAN ID2 A...

Page 23: ...ter in which the role is still protocol verification and forward transmission support Modbus protocol it is not Modbus host or slave machine the user can according to the protocol of Modbus communicat...

Page 24: ...Segment Counter Data 2 Character 1 Data 3 Character 2 Data 4 Character 3 Data 5 Character 4 Data 6 Character 5 Data 7 Character 6 Data 8 Character 7 Segment Mark The message is segmented message or a...

Page 25: ...s of Modbus RTU frame into CAN Bus long segment with the segmented CAN Bus protocol The user receives in the CAN Bus node take the function code and data processing domain can be For CAN Bus Modbus pr...

Page 26: ...AN BUS is half duplex so the data conversion process to ensure orderly on both sides of the bus data If both sides at the same time to send a large number of data bus converter will likely lead to inc...

Page 27: ...get help in the following ways Internet service Make a call to our technical office Return or replace product 7 1 Internet Service Please visit http www 3onedata com 7 2 Make a call to our technical o...

Reviews: