Width * Depth (mm)
500 x 700
SFT-150/200
Note: The above measurement is for recommendation only. The actual size for installation to be
determined based on site conditions.
3.1.4 Take the product out of the packing box and remove
all packing. Check the product for any damages that may
occur during transportation. Make sure that the equipment
is without any damage during the transport.
3.2 Installation of by-pass valve :
Locate the by-pass valve and in the accessory pack. Insert the 1” quick
connect nut, split ring and O-ring in the respective order shown in Fig3.2a.
3.1.5 To install and configure the softener, remove the upper lid
(Fig.3.1.4)
Fig. 3.1.4
.
Fig.3.2a Water Inlet Connector
O-ring
Split Ring
Fitting 1"
Plastic Male
NPT
1” Quick Connect Nut
The O-ring should be fitted into the 1” quick connect nut . And the 1” male NPT fitting connects to the
by-pass valve through the 1” quick connect nut. The by-pass valve assembly will then be connected to
the control valve body via the union connection (Fig 3.2a).
By-pass valve, Inlet and Outlet connector
Note: Do not use any tool to tighten the union connections.
Tightening by hand is sufficient.
3.1.3