![3M PROTEGE SG Operation And Maintenance Manual Download Page 54](http://html1.mh-extra.com/html/3m/protege-sg/protege-sg_operation-and-maintenance-manual_442734054.webp)
3M™ PROTÉGÉ SG
PORTABLE, REUSABLE SINGLE-GAS MONITOR
SPECIFICATIONS
087-0065, Rev D/February 2019
A-2
H
2
S hi res - Hydrogen Sulfide Sensor (high resolution)
Range
0 to 100 ppm, 0.1 ppm
Operating Temperature
-4°F to 122°F (-20°C to +50°C)
Operating Humidity
15% to 90% RH, non-condensing
CO - Carbon Monoxide Sensor (standard)
Range
0 to 1000 ppm
Operating Temperature
-4°F to 122°F (-20°C to +50°C)
Operating Humidity
15% to 90% RH, non-condensing
CO, Carbon Monoxide (hydrogen resistant)
Range
0 to 2000 ppm
Operating Temperature
-4°F to 122°F (-20°C to +50°C)
Operating Humidity
15% to 90% RH, non-condensing
HCN, Hydrogen Cyanide Sensor*
Range
0 to 100 ppm
Operating Temperature
-4°F to 122°F (-20°C to +50°C)**
Operating Humidity
15% to 90% RH, non-condensing
NO (Nitric Oxide) Sensor
Range
0 to 350 ppm
Operating Temperature
-4°F to 122°F (-20°C to +50°C)**
Operating Humidity
15% to 90% RH, non-condensing
NO
2
(Nitrogen Dioxide) Sensor
Range
0 to 100 ppm
Operating Temperature
-4°F to 122°F (-20°C to +50°C)**
Operating Humidity
15% to 90% RH, non-condensing
O3 (Ozone) Sensor
Range
0 to 3 ppm
Operating Temperature
-4.0 to +104°F (-20 to +40°C)
Operating Humidity
15% to 90% RH, non-condensing
PH
3
(Phosphine) Sensor
Range
0 to 20 ppm
Operating Temperature
-4°F to 122°F (-20°C to +50°C)**
Table A-2: Sensor Specifications