24
3M™ MicroTouch™ Controller RX151 Reference Guide
3M Touch Systems, Inc. Proprietary Information
Table 17. Command Status Field Entries
Response
Description
0
Failure in command processing
1
Command being processed
2
Stage 1 processing complete (for multi-stage commands).
3 Command
complete
4
Soft reset occurred
5
Hard reset occurred
6
Stage 2 processing complete (for multi-stage commands)
7 Not
used
Touch Status – Status information for the most recent coordinate. Information includes
whether the sensor is currently being touched.
Table 18. Power On Check Bit Fields
Bit Number
Description
0
1 if the sensor is being touched
1 Always
0
Set Feature - Reset
This is a request to perform a controller reset.
Table 19. Reset Request
Offset
Field
Size
Value
Description
0
bmRequestType
1
0x21
Host to device
1 bRequest 1
0x09
Set
Report
2
wValue
2
0x0303
03 = Feature
03 = Feature Report ID
4 wIndex
2
0 Always
0
6 wLength 2
8 Always
8
Table 20. Data Stage
Offset
Field
Size
Value
Description
0
bReport ID
1
0x03
Host to device
1
bmReport Subtype 1
0x07
Indicates a reset request
2 bResetType
1
0xXX
0x01=Soft
reset
3 Not
used 5
0 Not
used
Response
The device stalls endpoint 0 if the request cannot be processed successfully. The request