Sensor Status
Sensor Status refers to whether or not the sensor has been found and is operational.
Some of the possible messages include:
•
OK – Sensor found and operational.
•
BLK Error – Hardware error such as a checksum error in controller EEPROM.
•
CBL Error – Cable NOVRAM missing – this is only an error in systems requiring
cable NOVRAM.
•
HDW Error – Hardware error.
•
LIN Error – Linearity data error.
•
NOV Error – Checksum error in NOVRAM, using defaults.
•
PWM Error – Hardware error.
•
ROM Error – Checksum error in ROM.
•
SET Error – Unable to establish operating range at power-up.
Any other condition indicates a hardware failure. Contact Technical Support for more
information.