![background image](http://html1.mh-extra.com/html/3m/high-flow-series/high-flow-series_instructions-manual_444083040.webp)
40
Head & Manifold
# of
Cartridges
Rated
Flow
Flush Instructions
NH3 Series Head
1
2.1 gpm
(7,9 lpm)
Flush 4.2 gallons (15,9 liters) through cartridge(s)
before use (flush approx. 2 mins.)
VH3 Series Head
1
2.1 gpm
(7,9 lpm)
Flush 4.2 gallons (15,9 liters) through cartridge(s)
before use (flush approx. 2 mins.)
High Flow Series Twin
2XX
Manifold
2
4.2 gpm
(15,9 lpm)
Flush 8.4 gallons (31,8 liters) through cartridge(s)
before use (flush approx. 2 mins.)
High Flow Series Triple
3XX
Manifold
3
6.3 gpm
(23,8 lpm)
Flush 12.6 gallons (47,7 liters) through cartridge(s)
before use (flush approx. 2 mins.)
High Flow Series Single
DF1XX
Manifold
1
2.1 gpm
(7,9 lpm)
Flush 4.2 gallons (15,9 liters) through cartridge(s)
before use (flush approx. 2 mins.)
High Flow Series Twin
DF2XX
Manifold
2
4.2 gpm
(15,9 lpm)
Flush 8.4 gallons (31,8 liters) through cartridge(s)
before use (flush approx. 2 mins.)
High Flow Series Single
DP1XX
Manifold
1
2.1 gpm
(7,9 lpm)
Flush 4.2 gallons (15,9 liters) through cartridge(s)
before use (flush approx. 2 mins.)
High Flow Series Twin
DP2XX
Manifold
2
4.2 gpm
(15,9 lpm)
Flush 8.4 gallons (31,8 liters) through cartridge(s)
before use (flush approx. 2 mins.)
High Flow Series Triple
DP3XX
Manifold
3
6.3 gpm
(23,8 lpm)
Flush 12.6 gallons (47,7 liters) through cartridge(s)
before use (flush approx. 2 mins.)
High Flow Series Single
SF1XX
Manifold
1
2.1 gpm
(7,9 lpm)
Flush 4.2 gallons (15,9 liters) through cartridge(s)
before use (flush approx. 2 mins.)
High Flow Series
DIDF2XX
Manifold
2
4.2 gpm
(15,9 lpm)
Flush 8.4 gallons (31,8 liters) through cartridge(s)
before use (flush approx. 2 mins.)
System has been tested and certified by NSF International against NSF/ANSI Standard 42
for the reduction of the substances specified on the Performance Data Sheet
1
This model is not certified by WQA to WQA/ASPE/ANSI S-803.
Flush Table: HF65-CL