![background image](http://html1.mh-extra.com/html/3m/high-flow-series/high-flow-series_instructions-manual_444083032.webp)
32
Head & Manifold
# of
Cartridges
Rated
Flow
Flush Instructions
NH3 Series Head
1
1.5 gpm
(5,7 lpm)
Flush 3.0 gallons (11,4 liters) through cartridge(s)
before use (flush approx. 2 mins.)
VH3 Series Head
1
1.5 gpm
(5,7 lpm)
Flush 3.0 gallons (11,4 liters) through cartridge(s)
before use (flush approx. 2 mins.)
High Flow Series Twin
2XX
Manifold
2
3 gpm
(11,4 lpm)
Flush 6.0 gallons (22,7 liters) through cartridge(s)
before use (flush approx. 2 mins.)
High Flow Series Triple
3XX
Manifold
3
4.5 gpm
(17 lpm)
Flush 9.0 gallons (34,1 liters) through cartridge(s)
before use (flush approx. 2 mins.)
High Flow Series Single
DF1XX
Manifold
1
1.5 gpm
(5,7 lpm)
Flush 3.0 gallons (11,4 liters) through cartridge(s)
before use (flush approx. 2 mins.)
High Flow Series Twin
DF2XX
Manifold
2
3 gpm
(11,4 lpm)
Flush 6.0 gallons (22,7 liters) through cartridge(s)
before use (flush approx. 2 mins.)
High Flow Series Single
DP1XX
Manifold
1
1.5 gpm
(5,7 lpm)
Flush 3.0 gallons (11,4 liters) through cartridge(s)
before use (flush approx. 2 mins.)
High Flow Series Twin
DP2XX
Manifold
2
3 gpm
(11,4 lpm)
Flush 6.0 gallons (22,7 liters) through cartridge(s)
before use (flush approx. 2 mins.)
High Flow Series Triple
DP3XX
Manifold
3
4.5 gpm
(17 lpm)
Flush 9.0 gallons (34,1 liters) through cartridge(s)
before use (flush approx. 2 mins.)
High Flow Series Single
SF1XX
Manifold
1
1.5 gpm
(5,7 lpm)
Flush 3.0 gallons (11,4 liters) through cartridge(s)
before use (flush approx. 2 mins.)
High Flow Series
DIDF2XX
Manifold
2
3 gpm
(11,4 lpm)
Flush 6.0 gallons (22,7 liters) through cartridge(s)
before use (flush approx. 2 mins.)
System has been tested and certified by NSF International against NSF/ANSI Standard 42,
53 and/or CSA B483.1 for the reduction of the substances specified on the Performance
Data Sheet
1
This model is not certified by WQA to WQA/ASPE/ANSI S-803.
Flush Table: HF20-S
1
, HF20-MS
1
, HF25-S
1
, HF25-MS
1