![background image](http://html1.mh-extra.com/html/3m/high-flow-series/high-flow-series_instructions-manual_444083039.webp)
39
Head & Manifold
# of
Cartridges
Rated
Flow
Flush Instructions
NH3 Series Head
1
2.2 gpm
(8,3 lpm)
Flush 4.5 gallons (17,0 liters) through
cartridge(s) before use (flush approx. 2 mins.)
VH3 Series Head
1
2.2 gpm
(8,3 lpm)
Flush 4.5 gallons (17,0 liters) through
cartridge(s) before use (flush approx. 2 mins.)
High Flow Series Twin
2XX
Manifold
2
4.4 gpm
(16,7 lpm)
Flush 9.0 gallons (34,1 liters) through
cartridge(s) before use (flush approx. 2 mins.)
High Flow Series Triple
3XX
Manifold
3
6.6 gpm
(25 lpm)
Flush 13.5 gallons (51,1 liters) through
cartridge(s) before use (flush approx. 2 mins.)
High Flow Series Single
DF1XX
Manifold
1
2.2 gpm
(8,3 lpm)
Flush 4.5 gallons (17,0 liters) through
cartridge(s) before use (flush approx. 2 mins.)
High Flow Series Twin
DF2XX
Manifold
2
4.4 gpm
(16,7 lpm)
Flush 9.0 gallons (34,1 liters) through
cartridge(s) before use (flush approx. 2 mins.)
High Flow Series Single
DP1XX
Manifold
1
2.2 gpm
(8,3 lpm)
Flush 4.5 gallons (17,0 liters) through
cartridge(s) before use (flush approx. 2 mins.)
High Flow Series Twin
DP2XX
Manifold
2
4.4 gpm
(16,7 lpm)
Flush 9.0 gallons (34,1 liters) through
cartridge(s) before use (flush approx. 2 mins.)
High Flow Series Triple
DP3XX
Manifold
3
6.6 gpm
(25 lpm)
Flush 13.5 gallons (51,1 liters) through
cartridge(s) before use (flush approx. 2 mins.)
High Flow Series Single
SF1XX
Manifold
1
2.2 gpm
(8,3 lpm)
Flush 4.5 gallons (17,0 liters) through
cartridge(s) before use (flush approx. 2 mins.)
High Flow Series
DIDF2XX
Manifold
2
4.4 gpm
(16,7 lpm)
Flush 9.0 gallons (34,1 liters) through
cartridge(s) before use (flush approx. 2 mins.)
System has been tested and certified by NSF International against NSF/ANSI Standard 42,
53 and CSA B483.1 for the reduction of the substances specified on the Performance Data
Sheet
1
This model is not certified by WQA to WQA/ASPE/ANSI S-803.
Flush Table: HF60-CL
1
, HF60-CLS
1