6
78-8140-3820-0-B
4.5
Position and route the grounds to minimize
interference with cable ports and splicing. Cable
end ground connections are made after the
cables are installed in the base.
Note: The installation and removal of the 20mm-D
is the same for both the metallic and the non-
metallic versions. For demonstration purposes,
the metallic version will be used throughout the
instruction manual.
5.0 3M
™
External Cable Assembly Module (ECAM) Double 20 mm-D
Removal
5.1
Using a 3/8-inch (10 mm) nut driver, loosen the
clamp screws on the ECAM assembly. Pull the
clamps outward and rotate as shown. Lightly
re-tighten screw to hold clamps in place.
5.2
Loosen the three screws and separate the top and
bottom halves of the 20 mm ECAM double cable
assembly using a 3/8-inch (10 mm) nut driver.
Note: Keep the short screw in location shown
5.3
Loosen the three screws to remove the cable
clamp from the bottom half of the of the 20 mm
ECAM double cable assembly using a 3/8-inch
(10 mm) nut driver.