4
4.
Opening the closure
4.1.
method 1
Remove one blind plug if drop ports are not completely used.
Insert the screwdriver end (recommended width 8 mm) in the notch (Fig.8).
With the thumb, disengage one latch of the cover by pushing it towards the side (Fig.9 – mark 1).
Rotate the screwdriver by 90° (Fig.9 – mark 2).
Proceed the same to disengage the other latch on the other side (Fig.10 & 11).
Complete the cover removal by pulling it out to the top by using the screwdriver as a lever, until the cover comes
freely (Fig.12) and then remove it (Fig.13).
4.2.
method 2
Remove one blind plug if drop ports are not completely used.
Extract the cover by disengaging the latches and then by pushing the cover upward (Fig. 14, 15 and 16).
5.
Implementation of the mid span double cable entry
5.1 Use of single ECAM S12 in the dual entry port.
The dual entry port can also be used with two single ECAM S12.
Remove the protective cap.
Open the cable entry by knocking briefly on the screwdriver. (Fig.17).
Remove all plastic flash from the punch out area (avoid, use knife or
abrasives) before inserting the ECAM cable entry.
The entry port must be perfectly clean before inserting the cable entry.
For the preparation of the single cable entry ECAM S12, please refer to the
relevant instruction.
Push then turn Fig.9
8mm insert the screwdriver Fig.8
8mm insert the screwdriver Fig.10
Push then turn Fig.11
Lever effect Fig.12
90°
Disengage (1) then push (2) Fig.14
Detail (2) Fig.15
Extract the cover (pull) Fig.16
1
1
2
2
ECAM S12 in a dual entry Port Fig.17
90°
1
2
Extract the cover (pull) Fig.13