3
1.
Recommended installation tools
Please use the appropriate tools recommended by the cable manufacturer to prepare the cables.
Two flat end screwdriver (recommended width: 4 and 8mm) and one Torx
™
20 screwdriver.
Pressure tool kit (to perform a pressure flash test at 200mbar).
Leak detection fluid.
Additionally needed:
Wall mount: suitable dowels and screws
Pole mount: 20mm steel band
2.
Application
The enclosure is designed to:
Protect and manage bare fibres, micro-modules in organizers and splice trays.
Be installed in manhole, façade or pole applications.
3.
Fixing the splice enclosure
Mounting bracket is integrated to the base of the splice enclosure.
Wall mount or manhole applications
Depending on field configuration, consider using in priority a central
fixing point with an external one (recommended: 140 mm) (Fig.1).
Fasten the closure using 2 screws (Recommended diameter: 8mm)
according to the indicated axial distance.
Recommended distance between the axes: 140 mm
Recommended installation in manholes or façades (Fig. 2, 3 and 4).
Recommended installation on pole (Fig. 5, 6 and 7).
Attachment with metal band directly on pole or standard omega bracket.
Tighten both screws
Fig.4
Swivel until stopping on the
second screw
Fig.3
Install both screws (not completely
tightened), insert and slide over the
first screw
Fig.2
Pole front view
Fig.7
Side view pole
Fig.6
Fixing directly on the pole
Fig.5
1
2
3
1
Example
support
Fig.1
90
180
140
140
140