PREFACE

Manual Revision History

Date

Revision

Reason for Revision

November, 2013

A

Initial Issue

September, 2014

B

To add network switch requirements to the

WebApp section.

April, 2015

C

Various specification edits/updates.

490H Web App Configuration Page: Added

rows for secondary DNS and MAC address.

BI Activation instructions: added option to

activate 1295 BI using Attest™ BI Activator.

March, 2017

D

Revised to reflect reduced time for final

fluorescent result. Applicable to 3M™

Attest™ Auto-reader 490H software version

4.0.0 or greater.

Content Disclaimers

Pictorial Disclaimer

Sample printouts, graphics, displays and screens are for information and illustration

purposes only, and shall not be used for clinical or maintenance evaluations. Data shown

in sample printouts and screens do not reflect actual test results.

Hardware Disclaimer

The 3M™ Attest™ Auto

reader 490H hardware specifications are subject to change.

The system images, hardware components and hardware specifications included in

the manual may not match the system installed. Any changes or modifications to the

authorized system installation have been verified as compatible with the functionality

outlined in this document.

INTENDED USE

The 3M™ Attest™ Rapid Readout Biological Indicator System for Vaporized Hydrogen

Peroxide Sterilization provides rapid and reliable routine monitoring of vaporized hydrogen

peroxide sterilization processes in health care facilities. The system is comprised of an

incubator/reader with embedded software, the 3M™ Attest™ Auto

reader 490H, and a

biological indicator, the 3M™ Attest™ Rapid Readout Biological Indicator 1295.

INDICATIONS FOR USE

The 3M™ Attest™ Auto

reader 490H is designed to incubate and automatically read the

3M™ Attest™ Rapid Readout Biological Indicator 1295 at 60°C for a final fluorescent

result at 24 minutes.

PRODUCT DESCRIPTION

The 3M™ Attest™ Rapid Readout Biological Indicator System for Vaporized Hydrogen

Peroxide Sterilization provides rapid, reliable routine monitoring of hydrogen peroxide

vapor sterilization processes performed in health care facilities. The system is comprised

of a biological indicator and an incubator/reader (3M™ Attest™ Auto

reader 490H) with

embedded software. The 3M™ Attest™ Auto

reader 490H is designed to incubate and

automatically read 3M™ Attest™ Rapid Readout Biological Indicators 1295 at 60°C for a

final fluorescent result at 24 minutes.
The 3M™ Attest™ Auto

reader 490H is also designed to allow for further incubation

of positive control 3M™ Attest™ Rapid Readout Biological Indicators 1295 for a final

positive visual pH color change result at 24 hours. It is recommended that processed BIs

be transferred to a humidified incubator for further incubation. A final negative visual pH

color change result is assessed after 7 days. This further incubation is optional and not

intended for routine use.
A positive fluorescence reading or a positive visual pH color change result indicate a

sterilization process failure. However, due to the high sensitivity of the fluorescent result,

there is no advantage to continuing to incubate processed 3M™ Attest™ Rapid Readout

Biological Indicators 1295 once the fluorescent result has been documented.
Other biological indicators (BIs) are not compatible with this device and cannot be used.

WARRANTY

The 3M™ Attest™ Auto

reader 490H has a one year limited product warranty. The

US warranty, remedy and limitations are described in the Price Quote form and in the

Direct Price Pages. For countries outside of the US, any warranty is established by the

subsidiary with responsibility for service of the 3M™ Attest™ Auto

reader 490H.

Serial Number

For easy identification, each 3M™ Attest™ Auto

reader 490H has a unique serial number

printed on a label found on the back of the unit and displayed on the left side of the upper

row of text on the LCD display when the user depresses the

button. Please record

your serial number in this manual for future reference: ___________________.

SAFETY AND PRECAUTIONS

The 3M™ Attest™ Auto

reader 490H and its related devices and accessories are

designed to provide safe and reliable service when used according to the instructions

provided. Please read, understand, and follow all safety information contained in

the instructions for use included with the 3M™ Attest™ Auto

reader 490H and the

3M™ Attest™ Rapid Readout Biological Indicator 1295 devices prior to use. Use this

equipment only for the purpose described in this Operator

s Manual.

Retain these

instructions for future reference.

The unit is designed to be used only with the Power Supply module and Ethernet cable

supplied by 3M. If this product is used in a manner not specified, the protection provided

by the product may be impaired.

Explanation of Single Word Consequences

Warning:

 Indicates a hazardous situation, which, if not avoided, could result in

death or serious injury.

Caution:

 Indicates a hazardous situation, which, if not avoided, could result in

minor or moderate injury.

Warnings and Safety Precautions

The following warnings and precautions should be followed to avoid unsafe actions that

could result in personal injury or damage to the instrument.

WARNING:

To reduce the risk associated with hazardous voltage

Use indoors only.

Do not use the equipment if it is not working properly or if it has suffered any damage.

Use only the power supply specified for this product and certified for the country

of use.

CAUTION:

To reduce the risk of injury or instrument damage

Do not spill liquid onto or into the instrument. Do not immerse the unit in liquid.

Always unplug the 3M™ Attest™ Auto

reader 490H and allow to cool before cleaning.

Clean external surfaces using only the instructions provided by the manufacturer.

Do not open the instrument housing

 there are no user serviceable parts. The

instrument must be returned to the manufacturer for repair.

Wear safety glasses and gloves when activating the 3M™ Attest™ Rapid

Readout Biological Indicator 1295.

Summary of Contents for Attest Auto-reader 490H

Page 1: ...io 5Manual del operador 6Bedieningshandleiding 7Användarhandbok 8Brugsvejledning 9Brukerhåndbok 0Käyttöopas Manual do Utilizador Manual do Operador Εγχειρίδιο Χειριστή HInstrukcja obsługi FPříručka pro obsluhu SPriročnik za uporabo MИнструкция по эксплуатации Upute za korištenje dOperatör Kılavuzu I操作指南 jคู มือปฏิบัติงาน T작업자 매뉴얼 ...

Page 2: ......

Page 3: ...2 Product Description 2 Warranty 2 Safety and Precautions 2 Health and Safety Information 3 Explanation of Product and Packaging Label Symbols 3 Specifications 4 Instructions for Use 4 Features 7 Care and Cleaning 8 Troubleshooting Guide 8 Optional 3M Attest Auto reader 490H WebApp 9 Troubleshooting the 3M Attest Auto reader 490H WebApp 12 Repair and Replacement 12 ...

Page 4: ...fluorescence reading or a positive visual pH color change result indicate a sterilization process failure However due to the high sensitivity of the fluorescent result there is no advantage to continuing to incubate processed 3M Attest Rapid Readout Biological Indicators 1295 once the fluorescent result has been documented Other biological indicators BIs are not compatible with this device and can...

Page 5: ...H complies with the CE mark related to the Low Voltage Directive LVD 2006 95 EC as confirmed in the Declaration of Conformity The 3M Attest Auto reader 490H complies with the RoHS Directive Directive 2011 65 EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment The 3M Attest Auto reader 4...

Page 6: ...sed to sunlight or strong incandescent light Do not place instrument close to any device that emits a strong electro magnetic field Do not use on a vibrating surface Select Install Correct Power Plug The 3M Attest Auto reader 490H power supply comes with multiple blade configurations Install the blade configuration appropriate for your country into the power supply and plug into appropriate AC gro...

Page 7: ...etting Setting the 3M Attest Auto reader 490H Clock The 3M Attest Auto reader 490H date and time are displayed in this format YYYY MM DD HH MM with the time displayed using a 24 hour clock To change the year if necessary push the up or down buttons to set desired year then press to advance to the month adjust as necessary and press to advance to the day Use the button to move to the time and set t...

Page 8: ...ce the result is determined it is continuously displayed on the LCD panel until 10 seconds after the BI has been removed from the incubation well Note After the first minute of incubation if 3M Attest Rapid Readout Biological Indicator is inadvertently removed before the incubation period is complete an alarm will sound and a C2 Caution code will be displayed on the LCD panel under that well You m...

Page 9: ... positive 3M Attest Rapid Readout Biological Indicator results subsequently detected in other wells will result in the alarm sounding Removing the 3M Attest Rapid Readout Biological Indicator will reactivate the alarm for that well Pressing the Buzzer Alarm OFF button will not silence the alarm for error or caution code alarm warnings To disable the alarm see configuration section Stackable To sav...

Page 10: ...unit and plug it back in to clear error If error doesn t clear call for repair or replacement E3 Memory Error 3M Attest Auto reader 490H unable to save read data from memory Unplug the unit and plug it back in to clear error If error doesn t clear call for repair or replacement E7 Communications Error This error will occur if internal communications have failed Unplug the unit and plug it back in ...

Page 11: ...ddress URL Note To access the 3M Attest Auto reader 490H Web App within a secure network the PC or mobile device must have access to the secure network options include connecting via a network Ethernet cable signing in to the facility s wireless network or connecting via a virtual private network VPN A Serial number URL 1 Connect the supplied Ethernet cable from the 3M Attest Auto reader 490H to a...

Page 12: ...er 490H Web App Status History 3M Attest Auto reader 490H ATTEST 1295 ATTEST 1295 Auto reader 490H 1 2 3 4 5 24 6 7 8 9 10 SN 200299 2017 05 11 17 13 1 Open the Results Detail page After inserting a new 3M Attest Rapid Readout BI in the 3M Attest Auto reader 490H it is a best practice to open the 3M Attest Auto reader 490H Web App Results Detail page for that BI by clicking on the appropriate well...

Page 13: ...k on the desired radio buttons to change settings Language Selected setting indicates language in which text on 3M Attest Auto reader 490H Web App pages will appear on the PC mobile device screen Pushbutton Configuration Selecting Enable allows the user to configure the 3M Attest Auto reader 490H from the buttons on the unit itself Selecting Disable prevents the user from being able to configure t...

Page 14: ...cility virtual private network VPN on the mobile device Data entered by user on Results Detail page disappears User entered data is written to temporary web browser storage Browser may have cleared data Set web browser to accept allow or enable cookies As a best practice print or save Results Detail record as soon as BI result is final BI result displayed on 3M Attest Auto reader 490H LCD display ...

Page 15: ......

Page 16: ...t Paul MN 55144 1 800 228 3957 3M com Medical 3M Deutschland GmbH Health Care Business Carl Schurz Str 1 41453 Neuss Germany 2017 3M All rights reserved 3M and Attest are trademarks of 3M Used under license in Canada Issue Date 2017 03 34 8720 4946 4 ...

Reviews: