3M 8210Plus User Instructions Download Page 2

(English) 

1

W   

 WARNING

This respirator helps protect against certain particles. 

Misuse may result in sickness or death.

 For correct use, consult supervisor 

and these 

User Instructions

, or call 3M in U.S.A., 1-800-247-3941. In Canada, call Technical Service at 1-800-267-4414. In Mexico, call 

01-800-712-0646.

IMPORTANT

Before use, wearer must read and understand these 

User Instructions

. Keep these instructions for reference.

Use For

Particles such as those from grinding, sanding, sweeping, sawing, bagging, or processing minerals, coal, iron ore, flour, metal, wood, pollen, and 

certain other substances. Liquid or non-oil based particles from sprays that do not also emit oil aerosols or vapors. Follow all applicable local 

regulations. For additional information on 3M use recommendations for this class of respirator please consult the 3M Respirator Selection Guide found 

on the Personal Safety web site at www.3M.com/respiratorselector or call 1-800-243-4630 in U.S.A. In Canada, call 1-800 267-4414.

Do Not Use For

Do not use for gases and vapors, oil aerosols, asbestos, or sandblasting; particulate concentrations that exceed either 10 times the occupational 

exposure limit or applicable government regulations, whichever is lower. In the United States, do not use when the U.S. Occupational Safety and 

Health Administration (OSHA) substance specific standards, such as those for arsenic, cadmium, lead in the construction industry, or 4,4’-methylene 

dianiline (MDA), specify other types of respiratory protection. This respirator does not supply oxygen.

Biological Particles

This respirator can help reduce inhalation exposures to certain airborne biological particles (e.g. mold, 

Bacillus anthracis

Mycobacterium tuberculosis

etc.) but cannot eliminate the risk of contracting infection, illness or disease. OSHA and other government agencies have not established safe 

exposure limits for these contaminants.

Use Instructions

1.  Failure to follow all instructions and limitations on the use of this respirator and/or failure to wear this respirator during all times of exposure can 

reduce respirator effectiveness and 

may result in sickness or death.

2.  In the U.S., before occupational use of this respirator, a written respiratory protection program must be implemented meeting all the requirements 

of OSHA 29 CFR 1910.134, such as training, fit testing, medical evaluation, and applicable OSHA substance specific standards. In Canada, CSA 

standard Z94.4 requirements must be met and/or requirements of the applicable jurisdiction, as appropriate. Follow all applicable local regulations.

3.  The particles which can be dangerous to your health include those so small that you cannot see them.
4.  Leave the contaminated area immediately and contact supervisor if dizziness, irritation, or other distress occurs.
5.  Store the respirator away from contaminated areas when not in use.
6.  Inspect respirator before each use to ensure that it is in good operating condition. Examine all the respirator parts for signs of damage including 

the two headbands, attachment points, nose foam, and noseclip. The respirator should be disposed of immediately upon observation of damaged 

or missing parts. Filtering facepieces are to be inspected prior to each use to assure there are no holes in the breathing zone other than the 

punctures around staples and no damage has occurred. Enlarged holes resulting from ripped or torn filter material around staple punctures are 

considered damage. Immediately replace respirator if damaged. Staple perforations do not affect NIOSH approval (For 8110S only).

7.  Conduct a user seal check before each use as specified in the Fitting Instructions section. 

If you cannot achieve a proper seal, do not use the 

respirator. 

8.  Dispose of used product in accordance with applicable regulations. 

Use Limitations

1.  This respirator does not supply oxygen. Do not use in atmospheres containing less than 19.5% oxygen.
2.  Do not use when concentrations of contaminants are immediately dangerous to life and health, are unknown or when concentrations exceed 10 

times the permissible exposure limit (PEL) or according to specific OSHA standards or applicable government regulations, whichever is lower.

3.  Do not alter, wash, abuse or misuse this respirator.
4.  Do not use with beards or other facial hair or other conditions that prevent a good seal between the face and the sealing surface of the respirator.
5.  Respirators can help protect your lungs against certain airborne contaminants. They will not prevent entry through other routes such as the skin, 

which would require additional personal protective equipment (PPE).

6.  This respirator is designed for occupational/professional use by adults who are properly trained in its use and limitations. This respirator is not 

designed to be used by children.

Particulate Respirator N95

3

User Instructions

8210

Plus

/8210

Plus

MX/

8210/8210MX/07048/8110S

Summary of Contents for 8210Plus

Page 1: ...particules Directives d utilisation IMPORTANT Conserver ces directives d utilisation titre de r f rence Respirador para part culas N95 Instrucciones de uso IMPORTANTE Conserve estas Instrucciones par...

Page 2: ...ical evaluation and applicable OSHA substance specific standards In Canada CSA standard Z94 4 requirements must be met and or requirements of the applicable jurisdiction as appropriate Follow all appl...

Page 3: ...ps before placing respirator on the face 8210 8210MX only Fig 1 2 Cup the respirator in your hand with the nosepiece at your fingertips allowing the headbands to hang freely below your hand Fig 2 3 Po...

Page 4: ...ot exceed maximum use concentrations established by regulatory standards J Failure to properly use and maintain this product could result in injury or death M All approved respirators shall be selecte...

Page 5: ...Tout manquement aux directives et aux restrictions relatives l utilisation de ce respirateur pendant la dur e compl te de l exposition peut en diminuer l efficacit et provoquer des probl mes de sant o...

Page 6: ...reposage 20 C 4 F 30 C 86 F 80 86 F 30 C 4 F 20 C Humidit relative maximale pour l entreposage 80 HR Dur e maximale d utilisation Quitter imm diatement la zone contamin e et remplacer le respirateur s...

Page 7: ...espirateurs approuv s doivent tre choisis ajust s port s et entretenus conform ment aux normes de la MSHA de l OSHA de tout autre r glement en vigueur N Ne jamais substituer ou modifier ce respirateur...

Page 8: ...n Estados Unidos debe implantarse un programa escrito de protecci n respiratoria que cumpla con todos los requerimientos de la norma OSHA 29 CFR 1910 134 como capacitaci n prueba de ajuste evaluaci n...

Page 9: ...elo Instrucciones de ajuste Debe seguir estas instrucciones durante el tiempo que use el respirador 1 Pre estire la bandas superior e inferior antes de colocarse el respirador en la cara s lo 8210 Fig...

Page 10: ...Do not exceed maximum use concentrations established by regulatory standards J Failure to properly use and maintain this product could result in injury or death M All approved respirators shall be sel...

Page 11: ...w 3M com PPESafety 3M 02 2704 9011 10 OEL OSHA 4 4 4 4 methylene dianiline MDA OSHA 1 2 OSHA 29 CFR 1910 134 CSA Z94 4 3 4 5 6 NIOSH 8110S 7 8 1 19 5 2 IDLH 10 3 4 5 6 7 8 8210Plus 8210PlusMX 8210 821...

Page 12: ...2 ZH 8210Plus 8210PlusMX 8210 8210MX 07048 8110S 80 86 F 30 C 80 86 F 30 C 4 F 20 C 20 C 4 F 30 C 86 F 80 86 F 30 C 4 F 20 C 80 HR 1 8210 8210MX 2 3 4 W 5 4 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 3...

Page 13: ...r health C Do not exceed maximum use concentrations established by regulatory standards J Failure to properly use and maintain this product could result in injury or death M All approved respirators s...

Page 14: ...3 Partikulat yang berbahaya terhadap kesihatan termasuk partikulat yang halus dan tidak boleh dilihat dengan mata kasar 4 Tinggalkan kawasan yang tercemar dengan segera dan hubungi penyelia jika tera...

Page 15: ...2 Pegang respirator dengan menggunakan tangan dan jari anda pada bahagian klip hidung dan membenarkan pengikat kepala tergantung secara bebas di bawah tangan anda Gambarajah 2 3 Posisikan respirator d...

Page 16: ...eed maximum use concentrations established by regulatory standards J Failure to properly use and maintain this product could result in injury or death M All approved respirators shall be selected fitt...

Page 17: ...licence au Canada Produits de la Division des produits de protection individuelle de 3M pour usage en milieu de travail uniquement 3M M XICO S A DE C V AV SANTA FE NO 190 COL SANTA FE DEL LVARO OBREG...

Reviews: