2.0  Terminal Location and Mounting

2.1  Locate the terminal according to standard 

operating procedures. Consider the following 
points:

a) 

Locate the terminal inside the building as 
close as possible to cable entrance.

b) 

Locate the terminal on a firm mounting 
surface where it will be accessible to the 
technicians at all times; where it can be 
reached without a ladder; and where it will 
not project in a hazardous manner.

c) 

Observe caution when exposing the terminal 
to chemicals in liquid or vapor form as they 
may damage the plastic components.

CAUTION

Avoid locations near flammable materials, ignitable gases, 

dust, moisture, temperature extremes, moving machinery,  

electric light and power circuits, and electrical equipment.

2.2  Open the splicing chamber by loosening the bolt securing the splicing chamber door. Open the splicing chamber 

door. (See-fig. 7.02)

2.3  Pull the preterminated short stub, insulated ground wire, and accessories out of the splicing chamber.

2.4  Mount the terminal in designated position with the three mounting screws provided.

2.5  Remove the jumper wire retaining ring from poly bag and install in faceplate.

3.0  Feeder Cable Preparation and Strain Relief

3.1  Feeder cable diameters for the 3M

 Indoor Building Entrance Terminal (IBET) 4588V-QCS Series

PET Pair Count

Feeder Cable

       Minimum 

       Maximum 

       Diameter 

       Diameter

25

.42"

1.08"

50

.63"

1.45"

If the cable diameter is smaller than the minimum, use 3M

 130C tape to build up to the minimum.

3.2  Run the feeder cable 24" past the IBET terminal 

cable entry port.

3.3  Slide the 3M

 Pull ’N’ Shrink Tube (PST) on the 

end of the cable with the pull-tab away from the 
IBET terminal and temporarily keep it out of the 
way.

3.4  With the groove toward the IBET terminal and 

long end toward the cable, snap the cable gland 
halves around the cable. Slide the gland into the 
entry port of the IBET terminal.

3.5  Measure 2" of sheath past the gland inside the 

IBET terminal. Pull the gland and cable out of the 
IBET terminal.

843014

2"

25-50

pair

100 pair

Summary of Contents for 4588V-QCS Series

Page 1: ...Indoor Protected Building Entrance Terminal 4588V QCS Series with 3M Quick Connect System 2811 Dry Flame Retardant Block Instructions Underwriters Laboratories UL 348X Listed April 2010 78 0013 1813 4 A 3 ...

Page 2: ...10 Splicing System SD modules b Splice chamber for the feeder cable with cable strain relief Note diagram c Insulated 6 ground strap for the feeder cable d External bottom mounted three point ground bar and top mounted single point ground bar Note diagram e Numbered standard 5 pin protector receptacle field Note diagram f Binding post log and instruction label g The 3M Single Pair Test Probe and D...

Page 3: ...rt stub insulated ground wire and accessories out of the splicing chamber 2 4 Mount the terminal in designated position with the three mounting screws provided 2 5 Remove the jumper wire retaining ring from poly bag and install in faceplate 3 0 Feeder Cable Preparation and Strain Relief 3 1 Feeder cable diameters for the 3M Indoor Building Entrance Terminal IBET 4588V QCS Series PET Pair Count Fee...

Page 4: ...te Failure to properly bond and ground the terminal per N E C or local equivalent codes may render protection arrestors useless 4 2 Module splicing Splice per your company practice 4 3 Splice the feeder cable groups to the corresponding connectorized stubs according to your company s practice 4 4 3M Scotchlok Connector or individual connector splicing 4 5 Splice the feeder cable groups to the corr...

Page 5: ... least 5 cm 2 in of slack 6 4 Terminate the jumper wires to the distribution pair by repeating the procedure described in steps 3 1 and 3 2 6 5 Terminate additional jumper wires by repeating the above procedure 6 6 To remove jumper wires open the cap and pull the wires straight out from block 6 7 Route the wire below the connected cap 7 0 Installing the Electrical Protectors Note Use ONLY UL Recog...

Page 6: ... cover closed the exposed hasp allows for locking when security is required 9 0 3M Single Pair Test Probe 2827 9 1 Testing using 3M Single Pair Test Probe 2827 9 2 Plug the test probe into the cap of the pair being tested with the black lead to the left and the red lead to the right 10 0 3M Priority Caps 10 1 Priority Caps are used to designate special purpose circuits and prevent entry of the 3M ...

Page 7: ...tack the IBET terminal vertically up to three of the same cable pair count and within the diameter limits in the chart in 3 01 11 2 Mounting the IBET terminal a Mount the IBET terminal bodies using the cable glands to position them b Assemble the feeder cable strain relief according to Section 3 0 and prepare the feeder cable so that 21 of free conductor length will be in the last IBET terminal 1 ...

Page 8: ...8 78 0013 1813 4 A ...

Page 9: ...78 0013 1813 4 A 9 ...

Page 10: ...ranty Limited Remedy Limited Liability This product will be free from defects in material and manufacture for a period of one 1 year from the time of purchase 3M MAKES NO OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE If this product is defective within the warranty period stated above your exclusive remedy shall be at 3M s...

Reviews: