6.0 Running Jumpers 3M
™
Quick Connect System 2810 Block
6.1 Open the feeder pair jumper cap by pushing up on
the latch and rotating up. Insert jumper wire ends
A (tip) left and B (ring) right into wire openings in
the cap, making sure they are inserted all the way
to the back of the cap.
6.2 While holding the jumper wires in place, close the
cap and press to snap the latch firmly into place.
6.3 Route the jumper wires to the distribution pair
through wire loops on the block ends and through
vertical and horizontal wireways. Cut jumper
wires to appropriate length, leaving at least 5 cm
(2 in.) of slack.
6.4 Terminate the jumper wires to the distribution pair
by repeating the procedure described in steps 3.1
and 3.2.
6.5 Terminate additional jumper wires by repeating
the above procedure.
6.6 To remove jumper wires, open the cap and pull the
wires straight out from block.
6.7 Route the wire below the connected cap.
7.0 Installing the Electrical Protectors
Note: Use ONLY UL Recognized or Listed
protectors in the IBET.
7.1 The 3M
™
Indoor Building Entrance Terminal
(IBET) 4588V-QCS uses a standard five pin
protector receptacle field. The long pins of the
protector connect Tip and Ring from the feeder
cable though the protector to the short pins to the
distribution/house wire.
7.2 Insert protectors into the protector receptacle field
according to your company’s practice.