background image

SAFETY INFORMATION

EXPLANATION OF SIGNAL WORD CONSEQUENCES

WARNING

WARNING

CAUTION

CAUTION

CAUTION

IMPORTANT NOTES

Read, understand, and follow all safety information contained in these instructions prior to installation and 
use of the 3MDW101 Drinking Water System. Retain these instructions for future reference.
Intended use:

The 3MDW101 Drinking Water System is intended for use in fi ltering potable water in homes and has not been 
evaluated for other uses.  The system is installed at the point of use and typically installed under a sink.  System 
must be installed as specifi ed in the installation instructions by a qualifi ed professional.

Indicates a potentially hazardous situation, which, if not avoided, could result in 
death or serious injury and/or property damage.

Indicates a potentially hazardous situation, which, if not avoided, may result in minor 
or moderate injury and/or property damage.

Indicates a potentially hazardous situation, which, if not avoided, may result in 
property damage.

To reduce the risk associated with choking:

 • 

Do not

 allow children under 3 years of age to have access to small parts during the installation of this product.

To reduce the risk associated with ingestion of contaminants:

 • 

Do not

 use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or 

after the system.  Systems certifi ed for cyst reduction may be used on disinfected water that may contain fi lterable 
cysts.  EPA Establishment #070595-CT-001.

To reduce the risk associated with a hazardous voltage due to an installer drilling through existing electric 
wiring or water pipes in the area of installation:

 • 

Do not

 install near electric wiring or piping which may be in the path of a drilling tool when selecting the position to 

mount the fi lter bracket.

To reduce the risk associated with property damage due to water leakage:

 • 

Read and follow

 Use Instructions before installation and use of this system.

  •  Installation and use 

MUST

 comply with all state and local plumbing codes.

 • 

Protect fi lter from freezing

, remove replacement fi lter when temperatures are expected to drop below 40°F (4.4°C).

 • 

Do not

 install systems in areas where ambient temperatures may go above 110°F (43.3°C).

 • 

Do not install on hot water supply lines.

  The maximum operating water temperature of this fi lter system is 

100°F (37.8°C).

 • 

Do not install

 if water pressure exceeds 120 psi (827 kPa).  If your water pressure exceeds 80 psi (552 kPa), you 

must install a pressure limiting valve.  Contact a plumbing professional if you are uncertain how to check your 
water pressure.

 • 

Do not install 

where water hammer conditions may occur.  If water hammer conditions exist you must install a water 

hammer arrester.  Contact a plumbing professional if you are uncertain how to check for this condition.

  •  Where a backfl ow prevention device is installed on a water system, a device for controlling pressure due to thermal 

expansion must be installed.

 • 

Do not

 use a torch or other high temperature sources near fi lter system, cartridges, plastic fi ttings or 

plastic plumbing.

  •  On plastic fi ttings, never use pipe sealant or pipe dope.  Use PTFE thread tape 

only

, pipe dope properties may 

deteriorate plastic.

 • 

Do not

 install in direct sunlight or outdoors.

 • 

Do not

 install near water pipes which will be in path of a drilling tool when selecting the position to mount the bracket;

  •  Mount fi lter in such a position as to prevent it from being struck by other items used in the area of installation 

(waste baskets, etc.);

  •  Ensure that the location and fasteners will support the weight of the system when installed and full of water.
  •  Ensure all tubing and fi ttings are secure and free of leaks.
  •  Do not install unit if collet is missing. Contact 3M if collets are missing from any fi ttings.
  •  The disposable replacement fi lter 

MUST

 be replaced every 6 months, at the rated capacity or sooner if a notice-

able reduction in fl ow rate occurs.

  • Failure to follow instructions will void warranty.
  • Allow a minimum of 2.5” (6.4 cm) clear space under fi lter to facilitate fi lter change.
  • Install with the inlet and outlet ports as labeled.  Make sure not to reverse connections.

2

CAUTION

To reduce the risk of eye injury while drilling countertop for faucet installations:
 • 

Safety glasses 

MUST

 be worn during the sink hole drilling operations.

Summary of Contents for 3MDW101

Page 1: ...Installation and Operating Instructions For 3MDW101 Drinking Water System Homeowner Please retain for operation and future maintenance instructions ...

Page 2: ...reezing remove replacement filter when temperatures are expected to drop below 40 F 4 4 C Do not install systems in areas where ambient temperatures may go above 110 F 43 3 C Do not install on hot water supply lines The maximum operating water temperature of this filter system is 100 F 37 8 C Do not install if water pressure exceeds 120 psi 827 kPa If your water pressure exceeds 80 psi 552 kPa you...

Page 3: ...ucet GETTING STARTED FILTER REPLACEMENT 1 2 4 6 5 3 1 2 4 3 5 6 3 CAUTION To reduce the risk associated with property damage due to water leakage The disposable replacement filter MUST be replaced every 6 months at the rated capacity or sooner if a noticeable reduction in flow rate occurs Installation requires some household tools and novice plumbing skills If you replace your own kitchen and bath...

Page 4: ...nstalling the faucet 1 Slide the following parts in the order specified up blue tubing and threaded stem a Metal bezel b Large rubber washer 2 Next feed blue tubing and faucet stem down through faucet mount ing hole 3 From underneath sink assemble the black spacer star washer and hex nut as shown onto the threaded stem and tighten by hand 4 With a padded adjustable wrench turn the faucet base abov...

Page 5: ...h In Fittings To Attach Tubing Push tubing in as far as it will go Tubing must be inserted past o ring and hit backstop Pull tube to ensure it is secured CAUTION To reduce the risk associated with property damage due to water leakage Ensure all tubing and fittings are secure and free of leaks Figure 4 1 4 Blue Tubing 1 2 IPS Faucet Stem 1 2 IPS Cold Water Feed Tube Feedwater Adapter 4 Determine le...

Page 6: ...t filter into head Turn filter to the right clockwise until filter stops 4 Open the dedicated faucet and flush new replacement filter for four 4 gallons approximately 5 minutes before use It may sputter as it releases trapped air 5 Close dedicated faucet System is now under pressure and can be inspected for leaks Repair any leaks as needed before continuing The system is now ready for use FILTER R...

Page 7: ...g the warranty period 3M Purification Inc will replace the Product or refund your Product purchase price This warranty does not cover labor The remedy stated in this paragraph is Customer s sole remedy and 3M Purifica tion Inc s exclusive obligation This warranty gives you specific legal rights and you may have other rights which may vary from state to state or country to country For any warranty ...

Page 8: ...3M is a trademark of 3M Company 2012 3M Company All rights reserved INSTR8032 0512 3M Purification Inc 400 Research Parkway Meriden CT 06450 855 3M WATER 855 369 2837 www 3MWater com ...

Reviews: