background image

5

6.  Insert Blue Tubing from the 1/4” Feedwater Adapter into the fi lter INLET 

fi tting as shown in Figure 5. Refer to the “Using Push-In Fittings” section 
for detailed instructions.

7.  Insert tubing from faucet into the fi lter OUTLET fi tting as shown in Figure 

5.  Refer to the “Using Push-In Fittings” section for detailed instructions.

8.  Remove fi lter from box, and remove sanitary protective cap from replace-

ment fi lter.  Ensure both o-rings are present on the new fi lter and are 
seated into grooves; moisten o-rings with water.  DO NOT use any petro-
leum products to lubricate the o-rings.

9.  Align tabs of replacement fi lter with head assembly and insert replacement 

fi lter into head assembly.  Turn replacement fi lter to the right (clockwise) 
until it stops (about 1/4 turn).  The fi lter is now installed.  (See Figure 5).

10. Turn water supply back on from the shutoff valve on cold water line.  This 

will pressurize the fi lter system and begin sending fi ltered water to the 
faucet.  Look for leaks.  

If leaks occur, see Troubleshooting Guide.  Flush 

the fi lter for four (4) gallons (approx. 5 minutes).

INSTALLATION INSTRUCTIONS (CONTINUED)

INLET

OUTLET

Figure 5

To Release Tubing

Push in grey collet to release tubing. With collet 
held, pull tubing straight out.

Collet

Backstop

“Using Push-In Fittings”

To Attach Tubing

Push tubing in as far as it will go. Tubing must be inserted past 
o-ring and hit backstop. Pull tube to ensure it is secured.

CAUTION

To reduce the risk associated with property damage due to water leakage:
  •  Ensure all tubing and fi ttings are secure and free of leaks.

Figure 4

1/4” Blue 
Tubing

1/2” IPS

Faucet Stem

1/2” IPS 

Cold Water 

Feed Tube

Feedwater 

Adapter

4.  Determine length of tubing required from fi lter head as-

sembly to faucet and from water supply line to fi lter head 
assembly by holding tubing in place ensuring it is of ap-
propriate length.  Do not kink tubing as this will impede 
water fl ow.  If necessary, loop tubing around to avoid it 
being kinked.

 

Cut tubing straight with a utility knife.  (See Figure 3).

5.  Locate the cold water stem on the underside of the faucet 

fi xture.  Place basin or towel under the cold water supply 
valve.  Unscrew the cold water feed tube from the faucet 
stem.  Locate the 1/4” Feedwater Adapter that came with 
your Drinking Water System.  Insert the black gasket into 
the threaded adapter and tighten onto the 1/2” IPS Faucet 
Stem undersink, making sure that 1/4” side connection is 
accessible and not facing the wall.  Make sure not to over 
tighten.

 

Take the 1/2” IPS Cold Water Feed Tube and attach to the 
Feedwater Adapter, making sure not to over tighten.

 

Locate the 1/4” Blue Tubing and insert into the 1/4” out-
let of Feedwater Adapter (Figure 4).  See “Using Push-In 
Fittings.”

Correct

Incorrect

Figure 3

Summary of Contents for 3MDW101

Page 1: ...Installation and Operating Instructions For 3MDW101 Drinking Water System Homeowner Please retain for operation and future maintenance instructions ...

Page 2: ...reezing remove replacement filter when temperatures are expected to drop below 40 F 4 4 C Do not install systems in areas where ambient temperatures may go above 110 F 43 3 C Do not install on hot water supply lines The maximum operating water temperature of this filter system is 100 F 37 8 C Do not install if water pressure exceeds 120 psi 827 kPa If your water pressure exceeds 80 psi 552 kPa you...

Page 3: ...ucet GETTING STARTED FILTER REPLACEMENT 1 2 4 6 5 3 1 2 4 3 5 6 3 CAUTION To reduce the risk associated with property damage due to water leakage The disposable replacement filter MUST be replaced every 6 months at the rated capacity or sooner if a noticeable reduction in flow rate occurs Installation requires some household tools and novice plumbing skills If you replace your own kitchen and bath...

Page 4: ...nstalling the faucet 1 Slide the following parts in the order specified up blue tubing and threaded stem a Metal bezel b Large rubber washer 2 Next feed blue tubing and faucet stem down through faucet mount ing hole 3 From underneath sink assemble the black spacer star washer and hex nut as shown onto the threaded stem and tighten by hand 4 With a padded adjustable wrench turn the faucet base abov...

Page 5: ...h In Fittings To Attach Tubing Push tubing in as far as it will go Tubing must be inserted past o ring and hit backstop Pull tube to ensure it is secured CAUTION To reduce the risk associated with property damage due to water leakage Ensure all tubing and fittings are secure and free of leaks Figure 4 1 4 Blue Tubing 1 2 IPS Faucet Stem 1 2 IPS Cold Water Feed Tube Feedwater Adapter 4 Determine le...

Page 6: ...t filter into head Turn filter to the right clockwise until filter stops 4 Open the dedicated faucet and flush new replacement filter for four 4 gallons approximately 5 minutes before use It may sputter as it releases trapped air 5 Close dedicated faucet System is now under pressure and can be inspected for leaks Repair any leaks as needed before continuing The system is now ready for use FILTER R...

Page 7: ...g the warranty period 3M Purification Inc will replace the Product or refund your Product purchase price This warranty does not cover labor The remedy stated in this paragraph is Customer s sole remedy and 3M Purifica tion Inc s exclusive obligation This warranty gives you specific legal rights and you may have other rights which may vary from state to state or country to country For any warranty ...

Page 8: ...3M is a trademark of 3M Company 2012 3M Company All rights reserved INSTR8032 0512 3M Purification Inc 400 Research Parkway Meriden CT 06450 855 3M WATER 855 369 2837 www 3MWater com ...