27
2
E-Stop
2012 March
800rf-NA
9-OPERATION
(continued)
Important!
If, for any reason, the box should
stop inside the machine, the machine will stop
operating after 10 seconds. To remove the box
and restart, operate as follows:
- press the E-stop,
- open the safety guard,
- remove the box,
- close the safety guard an release the E-stops,
- press the AUXILIARIES push-button;
- press the RESET push-button,
- press the START (I) button to start the cycle
9.2 Operation Methods
The
800rf
works only in automatic:
- Safety guard closed,
- E-stop released,
- START (I) button pressed, air circuit open.
Automatic Operating Modes
- Unchanging box size (selector switch 10 on
1 pos.): the machine acknowledges the size of the
fi
rst box. The upper unit maintains its position along
whole production. Introducing a box of a different
size with consequent machine jam the same stop
after 10 seconds with activation of the ’‘cycle time
out’‘ warning light on the control board.
- Automatic (selector switch 10 on 2 pos.): the
machine acknowledges the box size whenever a
new box is placed on the infeed conveyor belt.
- Transit only (selector switch 10 on 3 pos): upper
taping unit out of operation; the box is sealed only
on the bottom side. Removing the bottom taping
unit the boxes can be simply moved inside-outside;
a useful condition when the sealing machine is
placed in an automatic packaging line.
9.3. Stop Methods
Normal Stop:
STOP (O) push button 6 on control board
panel: the push-button must be pressed at
the working cycle end.
To restart press RESET 4 then START 5.
EMERGENCY STOP:
Lockable E-stops pressed or safety guard open.
They stop the machine at any point of the cycle;
also pneumatic circuit are disconnected. To restart
release the E-stops and close the safety guards as
necessary and then:
- Press AUXILIARIES 3 push-button
- Press RESET 4 push-button,
- Press START 5 push-button
(Figure 9-11).
3
5
4
Figure 9-10
6
4
5
3
Figure 9-11
Summary of Contents for 3M-Matic 800rf
Page 4: ...THIS PAGE IS BLANK ...
Page 6: ...THIS PAGE IS BLANK ...
Page 8: ...8 THIS PAGE IS BLANK ...
Page 10: ...THIS PAGE IS BLANK ...
Page 58: ...46 THIS PAGE IS BLANK ...
Page 60: ...48 THIS PAGE IS BLANK ...
Page 62: ...50 THIS PAGE IS BLANK ...
Page 68: ...56 THIS PAGE IS BLANK ...
Page 70: ...58 THIS PAGE IS BLANK ...
Page 74: ...62 Figure 10440 800rf 2012 0DUFK 800rf NA ...
Page 110: ...98 THIS PAGE IS BLANK ...
Page 120: ...108 800rf 800rf NA 2012 March Figure 15087 11 10 12 7 2 3 3 1 3 6 6 5 5 8 4 9 13 3 ...
Page 122: ...THIS PAGE IS BLANK ...