![background image](http://html.mh-extra.com/html/3m/2250me-id/2250me-id_operators-manual_3044609041.webp)
78-8130-6151-8 Rev G
41
6. Press
Markr 2
[SK Toggle] to return to Dual Marker Locate.
F. 3M™ ID Marker Depth
1. Lower the tip of the receiver to the ground over the pinpointed marker.
2. Press
Depth
[SK].
−
The receiver will examine the marker
(Calculating, please wait...).
− If the marker is a 3M™ iD Marker, the
receiver will display the depth of the
marker, and its identification (serial)
number.
3.
To save the depth reading, press
Mem Select
[SK].
−
Five depth readings can be saved with the
time, date, and its identification number.
−
Save [SK] will place each entry in
sequential order in memory (M1 - M5)
until five readings have been stored. The
receiver will overwrite saved entries in
excess of five, beginning with M1.
4. Optional: Press
Clear All
[SK] to delete all stored depth information.
5. Press
Mem Select
[SK] to select a specific memory location (M1-M5) to store the
depth readings. When the preferred location appears on the display, press
Save
[SK]. The display and memory location will populate with the current information.
6. Each memory location can be reviewed by pressing
Mem Select
[SK].
7. Press
Locate
[5] to return to Marker Locate Mode.
G. Passive 3M Electronic Marker (Non-iD) Depth
1. Lower the tip of the receiver to the ground over the pinpointed marker.
2. Press
Depth
[SK].
−
The receiver will examine the targeted marker.
−
The display will instruct the operator to raise the unit 15.2 cm (6 inches) from
the ground.