![background image](http://html.mh-extra.com/html/3m/2250me-id/2250me-id_operators-manual_3044609014.webp)
14
78-8130-6151-8 Rev G
[13] Fault Finding Direction Indicators:
Corresponds to the 3M Earth Contact Frame
(A-Frame) probe (leg) colors.
[14] External Jack:
Port to connect cables from external devices such as the Earth
Contact Frame, a second 3M Dyna-Coupler, or toning coil.
[l5] Serial Port:
RS232 port to connect the receiver to a PC via serial cable or USB-to-
serial adapter cable.
[16]
Earphone Jack:
Will fit standard 1/8 inch (3.175 mm) mini-jack mono earphone
plug (not included).
4. Menu Screens
A. Main Menu
When the Menu [6] button is pressed, the Main Menu screen appears.
The function appears on the screen above each soft key.
1. Write Mode:
System used to write information to 3M iD Markers
2. Data/Template:
Displays marker history and
template creation/selection screens:
a. Read History
– 100 memory locations for
Read 3M iD Markers.
b. Write History
– 100 memory locations for
written 3M iD Markers.
c. User Templates
– Create and edit 3M iD
templates for 3M iD Markers. (max =32)
d. Trace Templates
– Create and edit
templates used to identify path. (max = 5)