1-8
To do…
Use the command…
Remarks
Configure the number of
probes per test
count
times
Optional
By default, each test makes one
probe.
Configure the maximum
number of history records that
can be saved
history-records
number
Optional
By default, the maximum number
is 50.
Configure the automatic test
interval
frequency interval
Optional
By default, the automatic test
interval is zero seconds,
indicating no automatic test will be
made.
Configure the probe timeout
time
timeout
time
Optional
By default, a probe times out in
three seconds.
Configure the type of service
tos value
Optional
By default, the service type is
zero.
Configure the type of FTP
operation
ftp-operation
{
get
|
put
}
Optional
By default, the type of FTP
operation is
get
, that is, the FTP
operation will get a file from the
FTP server.
Configure an FTP login
username
username
name
Configure an FTP login
password
password
password
Required
By default, neither username nor
password is configured.
Configure a file name for the
FTP operation
filename
file-name
Required
By default, no file name is
configured for the FTP operation
Start the test
test-enable
Required
Display test results
display hwping results
[
admin-name operation-tag
]
Required
You can execute the command in
any view.
4) Configuring HTTP test on HWPing client
Follow these steps to configure HTTP test on HWPing client:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enable the HWPing client
function
hwping-agent enable
Required
By default, the HWPing client
function is disabled.
Create a HWPing test group
and enter its view
hwping
administrator-name
operation-tag
Required
By default, no test group is
configured.