1-33
Figure 1-21
Front panel of the LSQ1SRP1CB0
(1)
(2)
(3)
(4)
(5)
(7)
(6)
(1) CF card slot and CFS LED
(2) Console port
(3) 10/100Base-TX Ethernet port for management and LEDs
(4) Power and fan status LEDs
(5) LPU status LEDs
(6) ACTIVE LED of LSQ1SRP1CB0
(7) RESET button
On-board interfaces
z
CF card slot
The CF card slot can accommodate a standard CF card (Type I or Type II), where you can store host
software and logs, and thus upgrade software conveniently. The CF card is hot swappable.
Table 1-52
describes the CFS LED on the right of the CF card.
Table 1-52
Description of the CFS LED
Status
Description
OFF
No CF card is in position.
ON
The CF card is in position.
z
Console port
Using an RJ-45 connector, the console port can be connected through a regular asynchronous serial
cable directly to a computer for system debugging, configuration, maintenance, management, and host
software loading, or to a modem for remote system debugging, configuration, maintenance and
management.
Table 1-53
Specifications of the console port
Item
Specifications
Connector type
RJ-45
Number of connectors
1
Interface standard
Asynchronous EIA/TIA-232
Baud rate
115,200 bps (defaulting to 9,600 bps)
Transmission distance
15 m (49.21 ft.)
Functions
z
It can be connected to an ASCII terminal.
z
It can be connected to a serial port of a local or
remote (through a pair of modems) PC running
terminal emulation program.
z
10/100Base-TX management Ethernet port