Maintenance and Repair
3-13
Replacing
the Power Supply
The Extended chassis comes with one power supply. A second power supply can
be installed as a backup. To replace the original power supply in your chassis,
follow the steps in Figure 3-12 and Figure 3-13.
CAUTION:
The following procedure is provided only for qualified service
personnel. There are no user serviceable parts inside the power supply.
WARNING:
Do not open the power supply. It contains hazardous voltages.
There are no user-serviceable parts inside.
VORSICHT:
Öffnen sie niemals das Netzteil. Hochspannung! Es sind keine zu
wartenden Teile enthalten.
AVERTISSEMENT:
Ne pas ouvrir ce bloc d’alimentation. Tensions dangereuses
à l’intérieur. Ne contient aucune pièce que l’utilisateur puisse rèparer.
PELIGRO:
No abra fuente de alimentación. Contiene alta tensión. No hay partes
para reemplazar adentro.
It is not necessary to remove the chassis if it is mounted in a rack.
CAUTION:
Installing a new power supply with the power switch in the on
position can result in arcing at the connectors, which can cause damage to the
power supply or the chassis.
Figure 3-12
Removing the Power Supply in the Extended Chassis
Detail
DIAGNOSTIC
®
CEC
Spring-loaded
plunger
Disengage plunger
while pulling power
supply out of chassis.
e
Remove front
panel.
a
Make sure power
switch is off.
b
Remove power cord.
c
Loosen captive
screw.
d
Summary of Contents for NETBuilder II