7-1
7
Maintaining Hardware
Preparing Tools
z
Phillips screwdrivers: P1-100mm, P2-150mm, P3-250mm
z
Flat-blade screwdrivers: P4-75mm
z
ESD-preventive wrist straps, ESD-preventive gloves
z
Antistatic bags, antistatic pads
Except an ESD-preventive wrist strap, none of the above installation tools are shipped with the device.
Precautions
z
Maintain the firewall hardware under the guidance of the local dealer or technical support
engineers appointed by H3C.
z
To avoid injuries, disconnect all power sources from the firewall before maintaining any hardware
modules of the firewall.
z
Always wear an ESD-preventive wrist strap or ESD-preventive gloves when maintaining the
firewall hardware. For more information, refer to the section talking about electrostatic discharge
prevention in Chapter 3 “Preparing for Installation.”
z
When installing or removing a demountable module, such as an MPU, an LPU, a memory module,
or a CF card, ensure good alignment with the slot and use uniform force to avoid damage to the
module.
z
Put the removed MPU, LPU, memory module, or CF card on an antistatic workbench with the PCB
side facing upward or place it in antistatic bags.
z
When checking or moving a removed MPU, LPU, memory module, or CF card, avoid touching any
components on the PCB.
Structure of the Firewall
Figure 7-1 shows the structure of the F5000-A5.