![3Com CommWorks 5210 User Manual Download Page 115](http://html1.mh-extra.com/html/3com/commworks-5210/commworks-5210_user-manual_441367115.webp)
Modem Tests
115
Receive Tone Test (-R)
Use the following command to receive a tone test:
tcmtone -R [-t] [-s
num] [-p num] target
Modem Tests
tcmtest -T
test [-s num] target
Query Current Test
Status
To query a modem to determine whether a test is already in progress, send the
following command:
tcmtest [-q]
target
Test Type (-T)
-T
test
Where:
test
= modem test type substring. Select from the following list of tests:
■
Local Analog Loop Back
■
Local Digital Loop Back
■
Remote Digital Loop Back
■
V54 Local Analog Loop Back
■
V54 Remote Digital Loop Back
■
Self Tests
■
Test RAM
■
Test ROM
■
Test NVRAM
■
Idle Phone Line Test
A substring match to the beginning of a command string has precedence over
internal matches. For example, "local analog" executes the Local Analog Loop
Back test, not the V54 Local Analog Loop Back test. Matching is case
insensitive. Spaces in the command name must be quoted properly according
to shell rules.
Duration (-s)
[-s
num]
num = number of seconds to remain in loop back mode. Default = 60