![3Com AirConnect User Manual Download Page 78](http://html.mh-extra.com/html/3com/airconnect/airconnect_user-manual_441084078.webp)
78
C
HAPTER
6: C
ONFIGURING
THE
AP U
SING
THE
ASCII I
NTERFACE
Enabling or Disabling
Encryption
The AP can be set for encryption of links to associated wireless clients. Any
wireless clients associated with the AP must also have encryption enabled and set
to the same level of encryption. To enable encryption in the AP, do the following:
1
Select
RF Configuration
from the Main menu.
2
Select
Enabled
for
WEP (Privacy)
to turn on encryption or
Disabled
for no encryption.
3
If you have enabled encryption, select
40 bit key
or
128 bit key (USA) or 40 bit key
(non-USA)
for
WEP Algorithm
.
4
Select
Save
to enter your selections, then answer
Yes
at the confirmation prompt.
5
Reset the AP as described in “Resetting an AP” on page 79 for your settings to
take effect.
Encryption
Configuration
Requirements
■
The encryption level (open, 40-bit, or 128-bit) must be the same on the
wireless client and the access point.
■
All Shared Keys on the wireless client must be the same as those on the access
point with which the client will associate. They must match exactly (key order
and hex-digit sequence).
■
The selected keys do not need to be the same among different clients and/or
access points.
Encryption Upgrade
Access Codes
If you are upgrading the access point from 40-bit encryption to 128-bit
encryption, you must enter an access code to perform the upgrade. Until the
access code is entered, you can only enable or disable 40-bit encryption.
1
From the Hyperterminal main menu, select
RF Configuration
.
2
Press the tab key to highlight
Enable Strong Encryption
.
3
Press
Enter
.
4
An access code entry screen appears. Enter the access code in the fields.
5
Select
Save
to save the access code entry.
6
If you have enabled encryption, select
128 bit shared key
for
WEP Algorithm
.
7
Select
Save
to enter your encryption algorithm, then answer
Yes
at the
confirmation prompt.
8
Reset the AP as described in “Resetting an AP” on page 79 for your settings to
take effect.
Special Configuration
Considerations
The following configuration settings are recommended for optimal performance.
Disable Short Preamble
If you are installing the access point into a network that includes earlier versions of
3Com access points, you must disable the short RF preamble setting (default is
enabled).
To disable short RF preamble:
1
Start Hyperterminal and connect to the access point.
2
From the Hyperterminal main menu, select
RF Configuration
.