58
C
HAPTER
4: C
REATING
AN
XRN S
TACKING
F
ABRIC
Table 14
SuperStack 4 Switch 5500 Support for XRN Distributed Fabric
1
Ensure that the Switch units that you wish to interconnect have the latest
software agent installed. You can use the
display version
command to check this.
2
Enable the ‘up port’ and the ‘down port’ on each Switch (see
Table 14
) to
operate in Fabric mode using the following
CLI command. From the
System View enter
fabric-port gigabitethernet 1/0/51
enable
,
for example.
As with all Switch 5500 CLI commands, the format for entering a
command that is port specific is x/y/z, where x = unit number, y = module
number (in the case of the Switch 5500 this will always be 0), z = port
number.
3
Connect the Fabric-enabled ‘up’ port on one Switch 5500 unit to the
Fabric-enabled ‘down’ port on another Switch 5500 unit using the
appropriate connection method for your Switch as detailed in
Table 14
.
4
To create a fully resilient Fabric: enable the spare Fabric ports on the
top-most and bottom-most units in the Fabric as described in the
previous steps. Then insert a cable into these two Fabric ports to create a
link between the top-most and bottom-most units in the Fabric, as shown
in
Figure 17
on
page 60
.
This ensures that in the event of a unit failure within the Fabric, the Fabric
will continue working and no “Fabric split” will occur.
5
Save all configuration settings. From the User View, enter the
save
command to save the configuration to your Switch.
Switch
Port used
XRN support
Switch 5500-SI 28-Port
(3C17151-91)
Ports 27 (up port) and 28
(down port) using a
1000 Mbps SFP transceiver
Only supports DDM
*
* Distributed Device Management
Switch 5500-SI 52-Port
(3C17152-91)
Ports 51 (up port) and 52
(down port) using a
1000 Mbps SFP transceiver
Only supports DDM*
Switch 5500-EI 28-Port
(3C17161-91)
Ports 27 (up port) and 28
(down port) using a
1000 Mbps SFP transceiver
Full XRN functionality
Switch 5500-EI 52-Port
(3C17162-91)
Ports 51 (up port) and 52
(down port) using a
1000 Mbps SFP transceiver
Full XRN functionality
DUA1715-0AAA02.book Page 58 Wednesday, March 23, 2005 11:17 AM
Summary of Contents for 5500-EI PWR
Page 12: ...12 ABOUT THIS GUIDE DUA1715 0AAA02 book Page 12 Wednesday March 23 2005 11 17 AM ...
Page 80: ...80 CHAPTER 6 UPGRADING SOFTWARE DUA1715 0AAA02 book Page 80 Wednesday March 23 2005 11 17 AM ...
Page 104: ...104 APPENDIX B PIN OUTS DUA1715 0AAA02 book Page 104 Wednesday March 23 2005 11 17 AM ...
Page 118: ...DUA1715 0AAA02 book Page 118 Wednesday March 23 2005 11 17 AM ...