2-3
Displaying and Maintaining Monitor Link
To do…
Use the command…
Remarks
Display monitor link group
information
display monitor-link group
{
group-id
|
all
}
Available in any view
Monitor Link Configuration Example
Network requirements
As shown in
Figure 2-1
:
z
Device C is dually uplinked to Device A through a smart link group.
z
It is required that when GigabitEthernet1/0/1 or GigabitEthernet1/0/2 of Device A fails, Device C
can sense the link failure and perform link switchover in the smart link group.
For detailed information about smart link, refer to
Smart Link Configuration
in the
High Availability
Volume
.
Figure 2-1
Network diagram for smart link in combination with monitor link configuration
Device A
Device B
Device C
Device D
GE1/0/1
GE1/0/2
GE1/0/1
GE1/0/2
GE1/0/1
GE1/0/2
GE1/0/1
GE1/0/2
Configuration procedure
1) Configuration on Device C
# Disable STP on GigabitEthernet 1/0/1 and GigabitEthernet 1/0/2 separately.
<DeviceC> system-view
[DeviceC] interface gigabitethernet 1/0/1
[DeviceC-GigabitEthernet1/0/1] undo stp enable
[DeviceC-GigabitEthernet1/0/1] quit
[DeviceC] interface gigabitethernet 1/0/2
[DeviceC-GigabitEthernet1/0/2] undo stp enable