65
A
Troubleshooting the NJ220
If you encounter problems with the IntelliJack:
■
Verify the IntelliJack is receiving power by viewing the Power LED (it should be on). If
the Power LED is not on, make sure that:
■
If using power over Ethernet, the other end of the network cable is plugged
into a switch on the network that has Power Over Ethernet integrated into it,
or one that feeds into an external midspan power supply that supports Power
Over Ethernet.
■
The local power supply is plugged into the IntelliJack and into a working
electrical outlet, if your network does not support Power Over Ethernet.
■
Verify the IntelliJack is connected to the network properly by viewing the Link LED (it
should be on). If the Link LED is not on, make sure the network cable:
■
Is terminated properly. Refer to the connector manufacturer’s instructions for
terminating the cable. Be sure to test the connector and verify it is working.
■
Has a valid connection to the network.
■
Adheres to proper length and cabling specifications for your network.
■
The IntelliJack is configured for manual MDI. Be sure to use a straight-through cable.
If you want to use a cross-connect cable, you must change settings in the
Configuration Manager software.
Troubleshooting Matrix
Event/Message
Description
Solution
Power LED is not on
IntelliJack is not receiving
power
■
Ensure power supply is properly
connected.
■
For power over Ethernet, make sure
that the cable is connected to both
the LAN port on the back of the
IntelliJack and to the workgroup
switch.
■
Make sure the upstream switch is
configured and active
Link LED is not on
IntelliJack has no connection
to the network
■
Make sure network cable is properly
terminated.
■
Make sure the IntelliJack is connected
to the network.
■
Make sure the cable is plugged into
the workgroup switch.
■
Make sure the upstream switch is
configured and active