Performing Initial Configuration
71
2
Build a PVC on the far-end PathBuilder S600 from the MCPU to the OC3 UNI (slot
1 to slot 3), setting the following parameters on the Add Virtual Circuit screen:
traffic shaper
—Choose any of the available values (for example 17M).
IP address
—You must use a different subnet than the one you used for the
near-end PathBuilder S600.
subnet mask
—Specify any acceptable address (for example, 255.255.255.0).
VPI/VCI
—You must use the same values as you did for the near-end PathBuilder
S600.
3
On the System Administration menu, set the following:
a
Set the default gateway on the far-end PathBuilder S600 to the PVC IP address
you set for the near-end PathBuilder S600 in step 1.
b
Set the default gateway on the management station to the local host IP address
of the near-end PathBuilder S600.
For details about setting the default gateway, see “Configuring the Default
Gateway” earlier in this chapter.
4
Apply your IP configuration changes.
a
From the main menu, select
[1] System Administration
.
b
From the System Administration menu, select
[3] Manage IP Network
Configuration
.
c
From the Manage IP Network Configuration menu, select
[1] Local Host IP
Configuration
.
d
From the Local Host IP Configuration menu, select
[3] Apply IP Configuration
Changes
.
In-band Management via the Near-end Dual Ethernet Module
To configure in-band management via the near-end PathBuilder S600 Dual
Ethernet module, follow these steps:
If you use this method, you can manage one PathBuilder S600 in a point-to-point
configuration or as many as 256 remote PathBuilder S600s if all the units are
connected to an ATM network service provided by a local or large Telco
organization.
1
Build a PVC on the near-end PathBuilder S600 from the Dual Ethernet Module
(port 1 or 2) to the OC3 UNI (for example, from slot 4 to slot 3), setting the
following parameters on the Add Virtual Circuit screen:
traffic shaper
—Choose any of the available values (for example 17M)
VPI/VCI
—Enter any values in the accepted range (for example, 10/101).
2
Attach a hub or Ethernet NIC directly to the Dual Ethernet Module port.
3
Build a PVC on the far-end PathBuilder S600 from the MCPU to the OC3 UNI (slot
1 to slot 3), setting the following parameters on the Add Virtual Circuit screen:
traffic shaper
—Choose any of the available values (for example 17M)
IP address
—Specify any acceptable address (for example, 192.198.65.3).
subnet mask
—Specify any acceptable address (for example, 255.255.255.0).
VPI/VCI
—You must use the same values as you did for the near-end PathBuilder
S600.
Summary of Contents for 3C63100-AC-C - PathBuilder S600...
Page 8: ...INDEX 3COM CORPORATION LIMITED WARRANTY ...
Page 14: ...xiv CHAPTER SUPPLEMENTARY REGULATORY INFORMATION ...
Page 18: ...18 ABOUT THIS GUIDE ...
Page 28: ...28 CHAPTER 1 SYSTEM DESCRIPTION ...
Page 74: ...74 CHAPTER 3 GETTING STARTED ...
Page 230: ...230 INDEX ...