Visiondome HD Installation Manual V2.1.29
Page 4
© 360 Vision Technology Ltd.
Power Connections
Connect 24Vac/30Vdc to CON3
Ethernet Connections
Connect Ethernet cable to HD Dome connection board
using a short bodied (13mm) RJ45 connector. Use colours
defined in 568B standard.
POE Ethernet Connections
Connect Ethernet cable to HD Dome connection board.
Use colours defined in 568B standard.
POE+ must support type 2.
RJ45
CAT5, CAT5e, CAT6 Cable
Signal
Pin 1
White with Orange Band
Tx+
Pin 2
Orange
Tx-
Pin 3
White with Green Band
Rx+
Pin 4
Blue
Pin 5
White with Blue Band
Pin 6
Green
Rx-
Pin 7
White with Brown Band
Pin 8
Brown
4 Connections
Suitable power cables
Cable Size
Internal VisionDome-HD
(No Heater)
Maximum Distances
(Using VDI-PSU)
0.75mm²
75 metres
1.00mm²
100 metres
1.25mm²
125 metres
1.50mm²
150 metres
2.00mm²
250 metres
To ensure optimum VisionDome-HD performance these parameters must be adhered to. Failure to do so will
invalidate the warranty.
Internal VisionDome-HD Connections
Use a short bodied RJ45 connector with CAT5e cable for the connection to the VisionDome-HD PCB 000-0125-
01. Do not use RJ45 connectors with connector hoods or CAT6 cable, as these are too bulky to fit properly.
The VisionDome-HD connection board is located at the top of the dome.