Manual WS.502 v1.5
2-Wire Energy Monitor
5
'
GATEWAY
'
: Normally this is the 3 first digits of your
IP address, and the last number '1'. (e.g. your IP
address is 192.168.0.123, then the GATEWAY
192.168.0.1)
If you do not fill this in correctly, there is no internet
on your web server.
'
SUBNET MASK
':
stands default at 255,255,255.0
This should only be changed if the web server is
connected to an extensive (sometimes industrial)
network. These settings are then communicated to
you by the IT technicians.
"
DNS SERVER"
: Fills in automatically when you've
checked
DHCP.
Usually this also works when you type
in the same IP address as your Gateway. (e.g.
192.168.0.1)
TIP:
You can go to the IP data of the PC and not take
over the IP address but Gateway, Subnet mask and
DNS server in the web server, or you can take it from
'Suggested for LOWI/server' from the server scanner.
FTP SERVER LOGS:
You may also want to forward the log data to a
remote FTP server. For this we have to work with an
IP address, or with a 'domain name'. The port number
is always '
21
' (e.g. 78.22.222.111:21)
IP FTP Log
Server : Enter the IP address of your FTP log
server here (port fix 21)
If you have a
domain name,
check the box for
'IP
FTP-LogServer
'
Domain Name
:
Enter domain name (e.g.
www.mijneigenftpserver.be')
Note If you don't get it working with a domain
name try
with the IP address of your domain
name.
FAQ describes how to find that IP
address via cmd ping :
wire.net/veel-gestelde-vragen/
In
send
ftp config,
if a valid domain name is filled in,
the found IP address will be filled in (e.g.
195.130.132.100:21)
Login Name - Pass: In the FTP server we also have to
(security) also set up a user, password and possibly a
folder where the data is stored.
After all, several web servers can log their data to the
same FTP server and then it is desirable that each
logger is assigned a folder for their data.
Of course, the login name, password and folder name
must also be the same in the FTP server. If the FTP
server has assigned a folder per user, the 'Dir Name'
must remain blank.
The length of the login is max 32 characters
(contiguous without special characters !)
The length of the password up to 22 characters, and
the folder up to 32 characters
RT LOG- CONSUMPTION LOG
1.
RT log
: stands for
RealTime.
This is only data
from connected modules and continuously
gives the current values according to set
interval
by i.f.v. the type of module: electrical
measurements (voltage-current-power-
reactive power
–
PF), temperatures, CO2,
humidity, pulse counters...
Interval adjustable between 5-60minutes
or'NO'.