2N Access Unit Installation Manual
80
/
107
•
•
•
•
•
•
•
•
•
•
Module
Minimum consumption [W]
Maximum consumption [W]
13.56 MHz RFID card reader
(583v2)
0.42
0.89
I/O module (577v2)
0.35
0.66
Tamper switch
0
0
Wiegand module (581v1)
x
x
Total
2.07
7.55
It is obvious from the specimen configuration that all the modules have sufficient outputs when
an external power supply is used. When a PoE supply is used, the power output is insufficient for
all the modules, which results in automatic decrease in backlight level, active output current
supply, volume and LED intensity.
Some modules need a specific power output for their specific activities: the I/O module, e.g.,
requires 0.13 W for relay closing (not included in the minimum consumption).
5 Buttons Module
The Buttons module (
Part No.
9155035
) is used for dialling selected Automation functions.
The module contains two bus connectors for
2N Access Unit
.
These two connectors are fully interchangeable and can be used either as inputs from the
basic unit or outputs to other modules.
If this module is the last one on the bus, one of the connectors remains unconnected.
The module package includes a 220 mm long interconnecting cable.
Keypad Module
The Keypad module (
Part No. 9155031
)
is used for a numeric access to the system.
The module contains two bus connectors for
2N Access Unit
.
These two connectors are fully interchangeable and can be used either as inputs from the
basic unit or outputs to other modules.
If this module is the last one on the bus, one of the connectors remains unconnected.
The module package includes a 220 mm long interconnecting cable.
Touch Keypad
The Touch keypad (
Part
No. 9155047
) provides a numerical input in the system.
The module contains two
2N Access Unit
bus connectors.
These two connectors are fully interchangeable and can be used both as inputs from the
main unit and outputs to other modules.
Summary of Contents for 01368-001
Page 1: ...2N Access Unit Installation Manual v 2 16 www 2n com ...
Page 45: ...2N Access Unit Installation Manual 45 107 ...
Page 46: ...2N Access Unit Installation Manual 46 107 Module flush mounting ...
Page 47: ...2N Access Unit Installation Manual 47 107 ...
Page 48: ...2N Access Unit Installation Manual 48 107 ...
Page 49: ...2N Access Unit Installation Manual 49 107 Wall surface mounting ...
Page 50: ...2N Access Unit Installation Manual 50 107 ...
Page 51: ...2N Access Unit Installation Manual 51 107 ...
Page 52: ...2N Access Unit Installation Manual 52 107 2 2 2 Two Module Box Flush mounting classic bricks ...
Page 53: ...2N Access Unit Installation Manual 53 107 ...
Page 56: ...2N Access Unit Installation Manual 56 107 ...
Page 57: ...2N Access Unit Installation Manual 57 107 Module flush mounting ...
Page 58: ...2N Access Unit Installation Manual 58 107 ...
Page 59: ...2N Access Unit Installation Manual 59 107 ...
Page 60: ...2N Access Unit Installation Manual 60 107 Wall surface mounting ...
Page 61: ...2N Access Unit Installation Manual 61 107 ...
Page 73: ...2N Access Unit Installation Manual 73 107 2N Access Unit Connectors PCB Version 586v2 ...