2N Access Unit Installation Manual
71
/
107
•
•
•
•
•
•
Factory Reset
Follow the instructions below
to
reset the factory default values
:
Press and hold the RESET button.
Wait until the red and green LEDs go on simultaneously and the acoustic signal
can be
heard (approx. 15–35 s).
Wait until the red LED goes off and the acoustic signal
can be heard (approx. for
another 3 s).
Wait until the green LED goes off and the red LED goes on again and the acoustic signal
can be heard (approx. for another 3 s).
Wait until the red LED goes off and the acoustic signal
can be heard (approx. for
another 3 s).
Release the RESET button.
•
Caution
In case of resetting the factory default settings on a device with a version of
firmware 2.18 or higher it is necessary to reprogram the
2N
®
Security Relay
using the instructions from section
.
Summary of Contents for 01368-001
Page 1: ...2N Access Unit Installation Manual v 2 16 www 2n com ...
Page 45: ...2N Access Unit Installation Manual 45 107 ...
Page 46: ...2N Access Unit Installation Manual 46 107 Module flush mounting ...
Page 47: ...2N Access Unit Installation Manual 47 107 ...
Page 48: ...2N Access Unit Installation Manual 48 107 ...
Page 49: ...2N Access Unit Installation Manual 49 107 Wall surface mounting ...
Page 50: ...2N Access Unit Installation Manual 50 107 ...
Page 51: ...2N Access Unit Installation Manual 51 107 ...
Page 52: ...2N Access Unit Installation Manual 52 107 2 2 2 Two Module Box Flush mounting classic bricks ...
Page 53: ...2N Access Unit Installation Manual 53 107 ...
Page 56: ...2N Access Unit Installation Manual 56 107 ...
Page 57: ...2N Access Unit Installation Manual 57 107 Module flush mounting ...
Page 58: ...2N Access Unit Installation Manual 58 107 ...
Page 59: ...2N Access Unit Installation Manual 59 107 ...
Page 60: ...2N Access Unit Installation Manual 60 107 Wall surface mounting ...
Page 61: ...2N Access Unit Installation Manual 61 107 ...
Page 73: ...2N Access Unit Installation Manual 73 107 2N Access Unit Connectors PCB Version 586v2 ...